Vitrification is currently a well-established technique for the cryopreservation of oocytes and embryos. It can be achieved either by direct (open systems) or indirect (closed systems) contact with liquid nitrogen. While there is not a direct evidence of disease transmission by transferred cryopreserved embryos, it was experimentally demonstrated that cross-contamination between liquid nitrogen and embryos may occur, and thus, the use of closed devices has been recommended to avoid the risk of contamination. Unfortunately, closed systems may result in lower cooling rates compared to open systems, due to the thermal insulation of the samples, which may cause ice crystal formation resulting in impaired results. In our study, we aimed to validate a newly developed vitrification device (Cryotop SC) that has been specifically designed for being used as a closed system. The cooling and warming rates calculated for the closed system were 5.254 °C/min and 43.522 °C/min, respectively. Results obtained with the closed system were equivalent to those with the classic Cryotop (open system), with survival rates in oocytes close to 100%. Similarly, the potential of the survived oocytes to develop up to good quality blastocysts after parthenogenetic activation between both groups was statistically equivalent. Assessment of the meiotic spindle and chromosome distribution by fluorescence microscopy in vitrified oocytes showed alike morphologies between the open and closed system. No differences were found either between the both systems in terms of survival rates of one-cell stage embryos or blastocysts, as well as, in the potential of the vitrified/warmed blastocysts to develop to full-term after transferred to surrogate females.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cryobiol.2018.02.002DOI Listing

Publication Analysis

Top Keywords

closed system
16
closed
8
oocytes embryos
8
open systems
8
closed systems
8
liquid nitrogen
8
survival rates
8
system
6
oocytes
5
embryos
5

Similar Publications

: This study evaluated changes in selected spatiotemporal and kinematic gait parameters and balance in girls with Adolescent idiopathic scoliosis (AIS) with and without the Chêneau brace. : 15 subjects with scoliosis wearing the Chêneau brace and an equal comparative control group underwent objective gait analysis with the 3D BTS motion caption system. Balance assessment was done with the Kistler platform.

View Article and Find Full Text PDF

Ion exchange membranes (IEMs) are permselective membranes that, in principle, only allow the flow of ions with a specific charge sign, opposite to that of the fixed membrane ionic groups (counter-ions). This charge-based selectivity, like the size-based selectivity of classic semipermeable membranes, leads to an uneven distribution of permeating ions on the two sides of the membrane, which allows for ion separation or recovery in various processes in industry or environmental protection. Here, we apply the principles of mass balance, charge neutrality, and equality of electrochemical potentials in the state of thermodynamic equilibrium to provide a simple method for estimating the Gibbs-Donnan factors and the equilibrium concentrations of permeating ions in two compartments separated by an ideal IEM, i.

View Article and Find Full Text PDF

QUEST#4X: An Extension of QUEST#4 for Benchmarking Multireference Wave Function Methods.

J Chem Theory Comput

January 2025

Qingdao Institute for Theoretical and Computational Sciences and Center for Optics Research and Engineering, Shandong University, Qingdao 266237, China.

Given a number of data sets for evaluating the performance of single reference methods for the low-lying excited states of closed-shell molecules, a comprehensive data set for assessing the performance of multireference methods for the low-lying excited states of open-shell systems is still lacking. For this reason, we propose an extension (QUEST#4X) of the radical subset of QUEST#4 ( , , 3720) to cover 110 doublet and 39 quartet excited states. Near-exact results obtained by iterative configuration interaction with selection and second-order perturbation correction (iCIPT2) are taken as benchmark to calibrate static-dynamic-static configuration interaction (SDSCI) and static-dynamic-static second-order perturbation theory (SDSPT2), which are minimal MRCI and CI-like perturbation theory, respectively.

View Article and Find Full Text PDF

Current researches on sodium penetration in electrolytic aluminum cathode carbon blocks primarily measure cathode expansion curves, showing mostly macroscopic characteristics. However, the microscopic structure is often underexplored. As a porous medium, the diffusion performance of cathode carbon blocks is closely tied to their internal pore structure.

View Article and Find Full Text PDF

GorillaFACS: The Facial Action Coding System for the Gorilla spp.

PLoS One

January 2025

Human Biology & Primate Cognition Department, Institute of Biology, Leipzig University, Leipzig, Germany.

The Facial Action Coding System (FACS) is an objective observation tool for measuring human facial behaviour. It avoids subjective attributions of meaning by objectively measuring independent movements linked to facial muscles, called Action Units (AUs). FACS has been adapted to 11 other taxa, including most apes, macaques and domestic animals, but not yet gorillas.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!