A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous Determination of Gatifloxacin and Prednisolone in their Bulk Powder, Synthetic Mixture and Their Combined Ophthalmic Preparation Using Micellar Liquid Chromatography. | LitMetric

A simple rapid and accurate micellar high performance liquid chromatographic method was improved and validated for the analysis of mixture containing gatifloxacin sesquihydrate (GTF) and prednisolone acetate (PRED) in their synthetic mixture and their combined preparation. The separation was achieved using a C18 column, micellar mobile phase consisted of 0.2 M sodium dodecyl sulfate, 12.5% n-propanol and 0.3% triethylamine in 0.02 M orthophosphoric acid at pH 7.0 at a flow rate of 1 ml/min with UV detection at 270 nm. The proposed method was found to be rectilinear over the concentration ranges of 5.0-45 μg ml-1 and 10-50 μg ml-1 with recovery percentage of 99.95 ± 0.82 and 100.07 ± 0.84 for GTF and PRED, respectively. The separation of both drugs was accomplished in a very short chromatographic run (<5 min), the method is reproducible (R.S.D. < 1.0%) and show satisfactory resolution between GTF and PRED (Rs) = 1.67. The developed method was validated according to International Conference on Harmonization (ICH) guidelines. The limit of detection of the proposed method was 0.33 and 0.21 μg ml-1, and the limit of quantitation was 0.99 and 0.64 μg ml-1 for GTF and PRED, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1093/chromsci/bmy011DOI Listing

Publication Analysis

Top Keywords

synthetic mixture
8
mixture combined
8
μg ml-1
8
simultaneous determination
4
determination gatifloxacin
4
gatifloxacin prednisolone
4
prednisolone bulk
4
bulk powder
4
powder synthetic
4
combined ophthalmic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!