OBJECTIVE To determine the maximum concentration (Cmax) of amikacin and time to Cmax (Tmax) in the distal interphalangeal (DIP) joint in horses after IV regional limb perfusion (IVRLP) by use of the cephalic vein. ANIMALS 9 adult horses. PROCEDURES Horses were sedated and restrained in a standing position and then subjected to IVRLP (2 g of amikacin sulfate diluted to 60 mL with saline [0.9% NaCl] solution) by use of the cephalic vein. A pneumatic tourniquet was placed 10 cm proximal to the accessory carpal bone. Perfusate was instilled with a peristaltic pump over a 3-minute period. Synovial fluid was collected from the DIP joint 5, 10, 15, 20, 25, and 30 minutes after IVRLP; the tourniquet was removed after the 20-minute sample was collected. Blood samples were collected from the jugular vein 5, 10, 15, 19, 21, 25, and 30 minutes after IVRLP. Amikacin was quantified with a fluorescence polarization immunoassay. Median Cmax of amikacin and Tmax in the DIP joint were determined. RESULTS 2 horses were excluded because an insufficient volume of synovial fluid was collected. Median Cmax for the DIP joint was 600 μg/mL (range, 37 to 2,420 μg/mL). Median Tmax for the DIP joint was 15 minutes. CONCLUSIONS AND CLINICAL RELEVANCE Tmax of amikacin was 15 minutes after IVRLP in horses and Cmax did not increase > 15 minutes after IVRLP despite maintenance of the tourniquet. Application of a tourniquet for 15 minutes should be sufficient for completion of IVRLP when attempting to achieve an adequate concentration of amikacin in the synovial fluid of the DIP joint.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.79.3.282DOI Listing

Publication Analysis

Top Keywords

dip joint
24
synovial fluid
16
minutes ivrlp
16
maximum concentration
8
concentration amikacin
8
amikacin synovial
8
distal interphalangeal
8
regional limb
8
limb perfusion
8
cmax amikacin
8

Similar Publications

In some occasions, outdoor steel structures like wind towers, bridges, winter sports facilities, and so on are subjected to extreme environmental conditions with the presence of ice and/or with below-zero temperatures. Sometimes in these situations, surface protection of the steel structure is usually designed using hot-dip galvanizing to improve its durability. In these special circumstances, the structure's connections are also exposed to adverse climatic agents.

View Article and Find Full Text PDF

Background: Mallet finger injuries, characterized by a flexion deformity caused by trauma to the extensor mechanism at the base of the distal phalanx, can lead to significant functional impairment if not treated appropriately. Surgical interventions for osseous mallet finger injuries often include techniques such as extension-block pinning and perioperative modifying plate fixation. When comparing these two methods, it is critical to assess factors such as technical ease, perioperative considerations, and postoperative outcomes.

View Article and Find Full Text PDF

Aims: ultrasound (US) diagnosis of enthesitis is burdened of low specificity, especially when it is performed in patients with psoriasis (PsO) but without clinical psoriatic arthritis (PsA), because of mechanical, dysmetabolic and age-related concurrent enthesopatic changes. We propose a novel US score to quantify the cortical-entheseal bone remodeling burden of several peripheral entheses, aiming to improve the specificity of US for PsA-related enthesitis, and to evaluate its diagnostic value in PsO patients with subsequent diagnosis of psoriatic arthritis (PsO/PsA).

Methods: clinical and US data of 119 consecutive patients with moderate/severe PsO and nonspecific musculoskeletal symptoms, were included in this retrospective study.

View Article and Find Full Text PDF

Background: Adhesion formation poses a significant challenge for both patients and hand surgeons following tendon repair. One common strategy to prevent adhesion formation is the use of physical barriers. This study aimed to compare the outcomes of extensor tendon repair with and without the application of the OrthoWrap bioresorbable Sheet, specifically in terms of adhesion prevention.

View Article and Find Full Text PDF

In order to investigate the influence of shear on contact characteristics and fluid flow evolution of rough rock fractures, a series of shear-flow tests were carried out by numerical experiments. Firstly, a sandstone specimen with a rough fracture was made in the laboratory, and the numerical model of the fracture was reconstructed in FLAC3D software. Experiments were conducted to investigate the depth of penetration of the fracture under different normal stress (1, 3, and 5 MPa) and shear displacement (2, 4, 6, 8, and 10 mm).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!