Treatment of advanced heart failure with implantable LVADs is increasing, driven by profound unmet patient need despite potential serious complications: bleeding, infection, and thrombus. The experimental objective was to develop a sensitive imaging approach to assess early thrombus accumulation in LVADs under operational high flow and high shear rates. : A monomeric bifunctional ligand with a fibrin-specific peptide, a short spacer, and Tc chelating amino acid sequence (F1A) was developed and compared to its tetrameric PEG analogue (F4A). Tc attenuation by LVAD titanium (1 mm) was 23%. Tc-F1A affinity to fibrin was K ~10 µM, whereas, the bound Tc-F4A probe was not displaced by F1A (120,000:1). Human plasma interfered with Tc-F1A binding to fibrin clot (p<0.05) in vitro, whereas, Tc-F4A targeting was unaffected. The pharmacokinetic half-life of Tc-F4A was 28% faster (124±41 min) than Tc-F1A (176±26 min) with both being bioeliminated through the urinary system with negligible liver or spleen biodistribution. In mice with carotid thrombus, Tc-F4A binding to the injured carotid was much greater (16.3±3.3 %ID/g, p=0.01) than that measured with an irrelevant negative control, Tc-I4A (3.4±1.6 %ID/g). In an LVAD mock flow-loop (1:1, PBS:human plasma:heparin) operating at maximal flow rate, Tc-F4A bound well to phantom clots in 2 min (p<0.05), whereas Tc-F1A had negligible targeting. Excised LVADs from patients undergoing pump exchange or heart transplant were rewired, studied in the mock flow loop, and found to have spatially variable fibrin accumulations in the inlet and outlet cannulas and bearings. Tc-F4A is a high-avidity prototype probe for characterizing thrombus in LVADs that is anticipated to help optimize anticoagulation, reduce thromboembolic events, and minimize pump exchange.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817118PMC
http://dx.doi.org/10.7150/thno.20271DOI Listing

Publication Analysis

Top Keywords

diagnosis lvad
4
lvad thrombus
4
thrombus high-avidity
4
high-avidity fibrin-specific
4
fibrin-specific probe
4
probe treatment
4
treatment advanced
4
advanced heart
4
heart failure
4
failure implantable
4

Similar Publications

Ovarian hemorrhage during antithrombotic therapy is sometimes difficult to manage. A 38-year-old woman, diagnosed with Marfan syndrome and implanted with a left ventricular assist device (LVAD) and taking aspirin and warfarin potassium, had a history of right adnexal oophorectomy via open surgery for a right ovarian hemorrhage at the age of 35 years. Thereafer, she had been treated with dienogest to suppress ovulation as much as possible.

View Article and Find Full Text PDF

Perioperative Stroke Following Implantation of Left Ventricular Assist Device: A Retrospective Cohort Study.

J Cardiothorac Vasc Anesth

November 2024

Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada; Department of Anesthesiology, Providence Health Care, Vancouver, BC, Canada.

Objectives: Stroke is common following left ventricular assist device (LVAD) implantation, although comprehensive data on perioperative strokes in this uncommon population is lacking. The current study aim was to characterize the presentation, features, and outcomes of perioperative cerebrovascular ischemia post-LVAD implantation at the authors' institution.

Design: Single-center retrospective cohort.

View Article and Find Full Text PDF
Article Synopsis
  • * Patients using LVADs face serious emergencies that need quick diagnosis and teamwork in treatment.
  • * This review provides a guide for recognizing and handling emergencies in LVAD patients, such as alarms, bleeding, strokes, and other critical issues.
View Article and Find Full Text PDF
Article Synopsis
  • An 18-year-old man with refractory cardiogenic shock from dilated cardiomyopathy was treated at the hospital through a paracorporeal left ventricular assist device (LVAD) implantation.
  • Post-surgery, he experienced loss of consciousness and was diagnosed with propionic acidemia after further evaluations revealed metabolic issues and brain imaging findings.
  • Following treatment for both his heart failure and propionic acidemia, his neurological and cardiac functions improved, leading to the successful removal of the LVAD; this case highlights the rare association between propionic acidemia and dilated cardiomyopathy in adults.
View Article and Find Full Text PDF
Article Synopsis
  • * Among 996 patients analyzed, those using the Impella 5.0/5.5 had significantly lower 30-day mortality rates compared to those using the smaller Impella 2.5/CP devices.
  • * The findings suggest that using the larger Impella 5.5 or upgrading from the smaller model could improve survival rates in patients with advanced AMI-CS on ECPELLA support.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?