Treatment of advanced heart failure with implantable LVADs is increasing, driven by profound unmet patient need despite potential serious complications: bleeding, infection, and thrombus. The experimental objective was to develop a sensitive imaging approach to assess early thrombus accumulation in LVADs under operational high flow and high shear rates. : A monomeric bifunctional ligand with a fibrin-specific peptide, a short spacer, and Tc chelating amino acid sequence (F1A) was developed and compared to its tetrameric PEG analogue (F4A). Tc attenuation by LVAD titanium (1 mm) was 23%. Tc-F1A affinity to fibrin was K ~10 µM, whereas, the bound Tc-F4A probe was not displaced by F1A (120,000:1). Human plasma interfered with Tc-F1A binding to fibrin clot (p<0.05) in vitro, whereas, Tc-F4A targeting was unaffected. The pharmacokinetic half-life of Tc-F4A was 28% faster (124±41 min) than Tc-F1A (176±26 min) with both being bioeliminated through the urinary system with negligible liver or spleen biodistribution. In mice with carotid thrombus, Tc-F4A binding to the injured carotid was much greater (16.3±3.3 %ID/g, p=0.01) than that measured with an irrelevant negative control, Tc-I4A (3.4±1.6 %ID/g). In an LVAD mock flow-loop (1:1, PBS:human plasma:heparin) operating at maximal flow rate, Tc-F4A bound well to phantom clots in 2 min (p<0.05), whereas Tc-F1A had negligible targeting. Excised LVADs from patients undergoing pump exchange or heart transplant were rewired, studied in the mock flow loop, and found to have spatially variable fibrin accumulations in the inlet and outlet cannulas and bearings. Tc-F4A is a high-avidity prototype probe for characterizing thrombus in LVADs that is anticipated to help optimize anticoagulation, reduce thromboembolic events, and minimize pump exchange.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817118 | PMC |
http://dx.doi.org/10.7150/thno.20271 | DOI Listing |
Case Rep Womens Health
December 2024
Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, 2-2, Yamada-oka, Suita City, 565-0871 Osaka, Japan.
Ovarian hemorrhage during antithrombotic therapy is sometimes difficult to manage. A 38-year-old woman, diagnosed with Marfan syndrome and implanted with a left ventricular assist device (LVAD) and taking aspirin and warfarin potassium, had a history of right adnexal oophorectomy via open surgery for a right ovarian hemorrhage at the age of 35 years. Thereafer, she had been treated with dienogest to suppress ovulation as much as possible.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
November 2024
Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver, BC, Canada; Department of Anesthesiology, Providence Health Care, Vancouver, BC, Canada.
Objectives: Stroke is common following left ventricular assist device (LVAD) implantation, although comprehensive data on perioperative strokes in this uncommon population is lacking. The current study aim was to characterize the presentation, features, and outcomes of perioperative cerebrovascular ischemia post-LVAD implantation at the authors' institution.
Design: Single-center retrospective cohort.
Trends Cardiovasc Med
December 2024
University of Kentucky, Lexington, KY, USA.
Int Heart J
December 2024
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kyushu University.
Int Heart J
December 2024
Second Department of Internal Medicine, University of Toyama.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!