AI Article Synopsis

  • The study utilized finite element analysis to evaluate the biomechanical stability of four different screw fixation techniques for the C1 and C2 vertebrae.
  • The C1 lateral mass-C2 pedicle screw (C1LM-C2PS) technique demonstrated the greatest reduction in range of motion (ROM) during flexion/extension and lateral bending, making it the most stable option.
  • The results suggest that if alternative fixation methods are used, surgeons may need to consider additional support to limit ROM and monitor stress at critical points on the screws.

Article Abstract

Study Design: Finite element analysis.

Objective: To compare the biomechanical stability imparted to the C1 and C2 vertebrae by the transarticular (TA), C1 lateral mass (LM)-C2 pedicle (PS), C1LM-C2 pars, and C1LM-C2 translaminar (TL) screw fixation techniques.

Summary Of Background Data: Cadaveric biomechanical studies of several atlantoaxial posterior fixation techniques have been performed, showing significant heterogeneity in biomechanical properties among the studies.

Methods: From computed tomography images, a nonlinear intact three-dimensional C1-2 finite element model was developed and validated. Four finite element models were reconstructed from different C1-2 fixation techniques. The range of motion (ROM) and maximum von Misses stresses for the four screw techniques were compared under flexion, extension, lateral bending, and axial rotation.

Results: C1LM-C2PS showed the greatest decrease in ROM with flexion/extension and lateral bending. C1-2TA and C1LM-C2 pars showed less ROM reduction than the other techniques, in flexion/extension. C1LM-C2TL showed the least decrease in ROM during axial rotation. For C1-2TA, the maximum stress was in the C1-2 joint region. In the C1LM-C2PS, the C1 rod head, C2 pars screw, and C2TL screw were stressed at the C2 rod head. The maximal von Mises stress on the C1-2TA at the C1-2 joint site was the highest at flexion/extension, whereas the C1LM-C2PS had the lowest stress on the screw at flexion/extension and lateral bending. The C1LM-C2TL showed the highest stress in axial rotation and lateral bending.

Conclusion: In this study, C1LM-C2PS fixation was the most stable technique. If surgeons have to use other fixation methods besides the C2 pedicle screw, they need to be aware that additional fixation or postoperative immobilization may be required to achieve ROM restriction. Careful observation at the maximum stress site on the screw including screw loosening, screw-bone interface disruption or screw fracture will be necessary during follow-up imaging examinations (x-ray and computed tomography scan) after atlantoaxial fixation.

Level Of Evidence: N/A.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000002584DOI Listing

Publication Analysis

Top Keywords

finite element
16
lateral bending
12
screw
9
atlantoaxial posterior
8
posterior fixation
8
c1lm-c2 pars
8
fixation techniques
8
computed tomography
8
decrease rom
8
flexion/extension lateral
8

Similar Publications

Bone tissue regeneration can be affected by various architectonical features of 3D porous scaffold, for example, pore size and shape, strut size, curvature, or porosity. However, the design of additively manufactured structures studied so far was based on uniform geometrical figures and unit cell structures, which often do not resemble the natural architecture of cancellous bone. Therefore, the aim of this study was to investigate the effect of architectonical features of additively manufactured (aka 3D printed) titanium scaffolds designed based on microtomographic scans of fragments of human femurs of individuals of different ages on in vitro response of human bone-derived mesenchymal stem cells (hMSC).

View Article and Find Full Text PDF

In this work, a cost-effective, scalable pneumatic silicone actuator array is introduced, designed to dynamically conform to the user's skin and thereby alleviate localised pressure within a prosthetic socket. The appropriate constitutive models for developing a finite element representation of these actuators are systematically identified, parametrised, and validated. Employing this computational framework, the surface deformation fields induced by 270 variations in soft actuator array design parameters under realistic load conditions are examined, achieving predictive accuracies within 70 µm.

View Article and Find Full Text PDF

Study Design: This study employed a patient-specific finite element model.

Purpose: To quantify the effect of anterior and posterior surgical approaches on adjacent segment biomechanics of the patient-specific spine and spinal cord.

Overview Of Literature: Adjacent segment degeneration (ASD) is a well-documented complication following cervical fusion, typically resulting from accelerated osteoligamentous deterioration and subsequent symptomatic neural compression.

View Article and Find Full Text PDF

Iontronic sensors based on confined space have garnered significant attention due to their promising applications, ranging from single-cell analysis to studies. However, their limited sensitivity has constrained their effectiveness in studying molecular information during physiological and pathological processes. Here, we demonstrate an electrolyte-gated ionic transistor (EGIT) by integrating the confined ion transport behavior in a double-barreled micropipet with an electrolyte-gated transistor configuration, achieving highly sensitive and selective sensing.

View Article and Find Full Text PDF

A Wireless Health Monitoring System Accomplishing Bimodal Decoupling Based on an "IS"-Shaped Multifunctional Conductive Hydrogel.

Small

January 2025

Engineering Research Center of Western Resource Innovation Medicine Green Manufacturing, Ministry of Education, School of Chemical Engineering, Northwest University, Xi'an, 710127, China.

Flexible wearable sensors with bimodal functionality offer substantial value for human health monitoring, as relying on a single indicator is insufficient for capturing comprehensive physiological information. However, bimodal sensors face multiple challenges in practical applications, including mutual interference between various modalities, and integration of excellent mechanical properties, interfacial adhesion, environmental adaptability and biocompatibility. Herein, the multifunctional hydrogel, synthesized through radical grafting and supramolecular self-crosslinking reactions, exhibits excellent thermal sensitivity (TCR = -1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!