A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Balloon-assisted ultrasonic localization: a novel technique for direct percutaneous endoscopic jejunostomy. | LitMetric

Direct percutaneous endoscopic jejunostomy (DPEJ) is a useful method for the establishment of enteral nutrition (EN) pathway. However, the identification of stomal puncture points for DPEJ is difficult. Here we present a case treated with an improved technique for DPEJ puncture-point localization, which was named DPEJ with balloon-assisted ultrasonic localization (DPEJ-BAUL). There were four steps after insertion of an endoscope into the jejunum: (1) a balloon dilatation catheter was inserted through the endoscope working channel; (2) the balloon was fully filled with water; (3) the site of puncture was selected with an ultrasonic probe percutaneously locating the water-filled balloon; and (4) a jejunostomy tube was placed by introducer technique. Rapid localization of a puncture site was possible with BAUL and the DPEJ procedure was successful. The patient's nutritional status was improved with EN and no postoperative complications were observed. DPEJ-BAUL is a feasible and effective technique to increase the technical success rate of DPEJ in patients with negative transillumination test results.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41430-018-0115-0DOI Listing

Publication Analysis

Top Keywords

balloon-assisted ultrasonic
8
ultrasonic localization
8
direct percutaneous
8
percutaneous endoscopic
8
endoscopic jejunostomy
8
dpej
6
localization
4
localization novel
4
technique
4
novel technique
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!