A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detonation Nanodiamonds as a New Tool for Phenol Detection in Aqueous Medium. | LitMetric

Detonation Nanodiamonds as a New Tool for Phenol Detection in Aqueous Medium.

J Nanosci Nanotechnol

Institute of Biophysics Siberian Branch of the Russian Academy of Sciences, Federal Research Center "Krasnoyarsk Science Center SB RAS", Akademgorodok, 660036 Krasnoyarsk, Russia.

Published: August 2018

This paper demonstrates the effectiveness of using detonation nanodiamonds (DNDs) for detecting phenol in aqueous medium. The study has shown that the catalytic effect of DNDs in the oxidative azo coupling reaction (phenol-4-aminoantipyrine-hydrogen peroxide) is produced by trace amounts of iron and copper ions adsorbed on the surface of nanoparticles. The effectiveness of DNDs as a catalyst is determined by the amounts of these adsorbates and can be enhanced by a factor of two by additional adsorption of these ions onto the nanoparticles. A rise in the temperature of the DND-catalyzed azo coupling reaction leads to a considerable (4.5-fold) increase in the reaction product yield. DNDs used to detect phenol in aqueous medium enable a linear increase in the yield of the product of the azo coupling reaction at concentrations of the analyte of between 0.05 and 10 μg/ml. The study demonstrates that DNDs can be reused to detect phenol in water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2018.15382DOI Listing

Publication Analysis

Top Keywords

aqueous medium
12
azo coupling
12
coupling reaction
12
detonation nanodiamonds
8
phenol aqueous
8
detect phenol
8
dnds
5
nanodiamonds tool
4
phenol
4
tool phenol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!