A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unilateral Arm Crank Exercise Test for Assessing Cardiorespiratory Fitness in Individuals with Hemiparetic Stroke. | LitMetric

Unilateral Arm Crank Exercise Test for Assessing Cardiorespiratory Fitness in Individuals with Hemiparetic Stroke.

Biomed Res Int

Department of Physical Therapy, School of Health Sciences, Shinshu University, 3-1-1 Asahi, Matsumoto-shi, Nagano 390-8621, Japan.

Published: August 2018

Cardiorespiratory fitness assessment with leg cycle exercise testing may be influenced by motor impairments in the paretic lower extremity. Hence, this study examined the usefulness of a unilateral arm crank exercise test to assess cardiorespiratory fitness in individuals with stroke, including sixteen individuals with hemiparetic stroke (mean ± SD age, 56.4 ± 7.5 years) and 12 age- and sex-matched healthy controls. Participants performed the unilateral arm crank and leg cycle exercise tests to measure oxygen consumption ([Formula: see text]O) and heart rate at peak exercise. The [Formula: see text]O at peak exercise during the unilateral arm crank exercise test was significantly lower in the stroke group than in the control group ( < 0.001). In the stroke group, the heart rate at peak exercise during the unilateral arm crank exercise test did not significantly correlate with the Brunnstrom recovery stages of the lower extremity ( = 0.137), whereas there was a significant correlation during the leg cycle exercise test (rho = 0.775, < 0.001). The unilateral arm crank exercise test can detect the deterioration of cardiorespiratory fitness independently of lower extremity motor impairment severity in individuals with hemiparetic stroke. This study is registered with UMIN000014733.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804117PMC
http://dx.doi.org/10.1155/2017/6862041DOI Listing

Publication Analysis

Top Keywords

unilateral arm
24
arm crank
24
exercise test
24
crank exercise
20
cardiorespiratory fitness
16
individuals hemiparetic
12
hemiparetic stroke
12
leg cycle
12
cycle exercise
12
lower extremity
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!