Introduction: Both hip resurfacing arthroplasty (HRA) and large-diameter head metal-on-metal total hip arthroplasty (LDH MoM THA) are generally used for young and active patients. A number of comparative studies of HRA and total hip arthroplasty have been published in the literature. However, studies that have compared HRA with LDH MoM THA are rare. The purpose of this study is to compare the mid-term results of HRA with those of LDH MoM THA in young patients.
Patients And Methods: Between 2007 and 2011, 68 patients were enrolled in the study and randomized into two groups: HRA group (28 hips) and LDH MoM THA group (40 hips). Peri-operative data including blood loss, surgery duration, size of the implant, and post-operative complications were recorded. All patients were assessed clinically and radiologically at six weeks; one, three and five years; and at the time of final review. Functional outcome were assessed using Harris hip (HHS), University of California Los Angeles (UCLA) and Oxford hip (OHS) scores. The mean follow-up for all patients was 7.4 years (5 to 9).
Results: Patient groups matched similarly in age, percent female, body mass index, preoperative HHS, and follow-up time. No differences were observed between the two groups in blood loss or in head size or acetabular inclination angle. HRA group had significantly longer surgery duration but less blood loss. The two groups had comparable HHS, UCLA, and OHS at the latest follow-up. Major complications, such as fracture, dislocation, infection, and adverse reactions to the metal debris (ARMD) were not found in the two groups. Only one case in LDH MoM THA group underwent revision surgery due to unexplained pain.
Conclusion: Comparison of HRA and LDH MoM THA shows similar mid-term clinical results. HRA may be preferable due to the well-preserved bone stock and restoration of the native anatomy. LDH MoM THA may be used with caution due to the excessive metal ion release.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00264-018-3819-9 | DOI Listing |
Nano Lett
December 2024
State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, P. R. China.
J Clin Med
January 2023
Department of Orthopaedics, The Orthopaedic Research Foundation of Western Australia (ORFWA), Fiona Stanley Hospital, 6150 Perth, Australia.
Background: The aim of this study is to update the 10-year follow-up survivorship and metal ions levels of a cohort of metal-on-metal (MoM) hip resurfacing (HR) and large-diameter-head (LDH) total hip arthroplasty (THA).
Methods: The study is a retrospective analysis of prospectively collected data that compared the outcomes of 24 MoM HR (21 patients) and 15 (11 patients) modular LHD MoM THA at >10 years follow-up. Baseline characteristics as well as intraoperative and postoperative information were collected, including complications, revisions, clinical and radiographic outcomes, and serum metal ions level (Cobalt, Chromium).
Small
March 2023
State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, Beijing, 100029, P. R. China.
Converting CO to clean-burning fuel such as natural gas (CH ) with high activity and selectivity remains to be a grand challenge due to slow kinetics of multiple electron transfer processes and competitive hydrogen evolution reaction (HER). Herein, the fabrication of surfactants (C H COONa, C H SO Na, C H SO Na) intercalated NiAl-layered double hydroxides (NiAl-LDH) is reported, resulting in the formation of LDH-S1 (S1 = C H COO ), LDH-S2 (S2 = C H SO ) and LDH-S3 (S3 = C H SO ) with curved morphology. Compared with NiAl-LDH with a 1.
View Article and Find Full Text PDFArch Orthop Trauma Surg
July 2023
Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, PO Box 1777, 70211, Kuopio, Finland.
Introduction: The aim of this retrospective study was to study the long-term survival and reasons for revisions of a single-type, large-diameter head (LDH) metal-on-metal (MoM) implant. A special study interest was to find the threshold level for revision in terms of adverse reaction to metal debris (ARMD).
Materials And Methods: In this cohort study, we retrospectively reviewed 234 patients (253 hips) who received 38 mm head size LDH MoM total hip arthroplasties (THAs) between 01 January 2004 and 31 December 2009 at our institution.
Acta Orthop
April 2022
Department of Orthopaedics and Traumatology, Turku University Hospital; University of Turku.
Background And Purpose: We have previously reported that the whole blood (WB) chromium (Cr) and cobalt (Co) ion levels decrease in the short term after ReCap-M2a-Magnum large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA). This study reports long-term metal ion levels and clinical outcomes after ReCap-Magnum THA.
Patients And Methods: ReCap-M2a-Magnum LDH THA was used in 1,450 patients in our hospital district from 2005 to 2012.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!