CRT-D oversensing storm by contacted electromagnetic interference.

Hellenic J Cardiol

Cardiology Department, Patras University Hospital, 26500 Rion, Patras, Greece. Electronic address:

Published: August 2020

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hjc.2018.02.005DOI Listing

Publication Analysis

Top Keywords

crt-d oversensing
4
oversensing storm
4
storm contacted
4
contacted electromagnetic
4
electromagnetic interference
4
crt-d
1
storm
1
contacted
1
electromagnetic
1
interference
1

Similar Publications

Background: Left bundle branch pacing (LBBP) has been suggested as an alternative modality for biventricular pacing in cardiac resynchronization therapy (CRT)-eligible patients. As it provides stable R-wave sensing, LBBP has been recently used to provide sensing of ventricular arrhythmia in patients receiving implantable cardioverter-defibrillator (ICD) with CRT.

Objective: The aim of this study was to analyze the long-term safety and efficacy of the LBBP lead for appropriate detection of ventricular arrhythmia and delivery of antitachycardia pacing (ATP) in patients requiring defibrillator therapy with CRT.

View Article and Find Full Text PDF

Introduction: Diaphragmatic myopotential oversensing (dMPO) by implantable cardioverter defibrillators (ICDs) is thought to be a rare condition that can be misdiagnosed as lead failure and lead to unnecessary lead replacement. We observed several cases of dMPO in patients with Sorin/LivaNova ICDs (MicroPort Sci.).

View Article and Find Full Text PDF

Aims: In patients with a functional Sprint Fidelis lead at generator replacement, the manufacturer recommended to either continue to use the existing lead or replace it with a new lead. For those patients who continue to use a functional Fidelis lead, the risk of inappropriate shocks remains present if the lead fails in the future. We evaluated the feasibility of an alternative approach at the time of cardiac resynchronization therapy-defibrillator (CRT-D) generator replacement in patients with a functional bipolar left ventricular (LV) lead for prevention of inappropriate shocks from future Fidelis lead failure.

View Article and Find Full Text PDF

Introduction: Expert consensus holds that post-market, systematic surveillance of ICD leads is essential to ensure confirmation of adequate lead performance. GALAXY (NCT00836589) and CELESTIAL (NCT00810264) are ongoing multicenter, prospective, non-randomized registries conducted to confirm the long-term safety and reliability of Biotronik leads.

Methods And Results: ICD and CRT-D patients are followed for Linox and Linox(smart) ICD lead performance and safety for 5 years post-implant.

View Article and Find Full Text PDF