Retention prediction in reversed phase high performance liquid chromatography using quantitative structure-retention relationships applied to the Hydrophobic Subtraction Model.

J Chromatogr A

Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences-Chemistry, University of Tasmania, Private Bag 75, Hobart, 7001, Australia. Electronic address:

Published: March 2018

Quantitative Structure-Retention Relationships (QSRR) methodology combined with the Hydrophobic Subtraction Model (HSM) have been utilized to accurately predict retention times for a selection of analytes on several different reversed phase liquid chromatography (RPLC) columns. This approach is designed to facilitate early prediction of co-elution of analytes, for example in pharmaceutical drug discovery applications where it is advantageous to predict whether impurities might be co-eluted with the active drug component. The QSRR model utilized VolSurf+ descriptors and a Partial Least Squares regression combined with a Genetic Algorithm (GA-PLS) to predict the solute coefficients in the HSM. It was found that only the hydrophobicity (η'H) term in the HSM was required to give the accuracy necessary to predict potential co-elution of analytes. Global QSRR models derived from all 148 compounds in the dataset were compared to QSRR models derived using a range of local modelling techniques based on clustering of compounds in the dataset by the structural similarity of compounds (as represented by the Tanimoto similarity index), physico-chemical similarity of compounds (represented by log D), the neutral, acidic, or basic nature of the compound, and the second dominant interaction between analyte and stationary phase after hydrophobicity. The global model showed reasonable prediction accuracy for retention time with errors of 30 s and less for up to 50% of modeled compounds. The local models for Tanimoto, nature of the compound and second dominant interaction approaches all exhibited prediction errors less than 30 s in retention time for nearly 70% of compounds for which models could be derived. Predicted retention times of five representative compounds on nine reversed-phase columns were compared with known experimental retention data for these columns and this comparison showed that the accuracy of the proposed modelling approach is sufficient to reliably predict the retention times of analytes based only on their chemical structures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2018.01.053DOI Listing

Publication Analysis

Top Keywords

retention times
12
models derived
12
reversed phase
8
liquid chromatography
8
quantitative structure-retention
8
structure-retention relationships
8
hydrophobic subtraction
8
subtraction model
8
predict retention
8
co-elution analytes
8

Similar Publications

Ultralow Power Cold-Fuse Memory Based on Metal-Oxide-CNT Structure.

Nano Lett

January 2025

Key Lab for the Physics and Chemistry of Nanodevices and Center for Carbon-based Electronics, School of Electronics, Peking University, Beijing 100871, China.

One-time programmable (OTP) memory is an essential component in chips, which has extremely high security to protect the stored critical information from being altered. However, traditional OTP memory based on the thermal breakdown of the dielectric has a large programming current, which leads to high power consumption. Here, we report a gate tunneling-induced "cold" breakdown phenomenon in carbon nanotube (CNT) field-effect transistors, and based on this we construct a "cold" fuse (C-fuse) memory where applying a mild gate voltage can break down the CNT channel without damaging the gate dielectric.

View Article and Find Full Text PDF

Mind mapping stands as a contemporary approach to education, introducing an innovative means of teaching and learning. In current times, this technique is embraced due to its ability to enhance the learning and retention process. This investigation explored the imperative nature of adopting novel educational methodologies such as mind mapping, while also examining its benefits and constraints.

View Article and Find Full Text PDF

The early treatment of Osteonecrosis of Femoral Head (ONFH) remains a clinical challenge. Conventional Bone Marrow Mesenchymal Stem Cell (BMSC) injection methods often result in unsatisfactory outcomes due to mechanical cell damage, low cell survival and retention rates, inadequate cell matrix accumulation, and poor intercellular interaction. In this study, we employed a novel cell carrier material termed "3D Microscaffold" to deliver BMSCs, addressing these issues and enhancing the therapeutic effects of cell therapy for ONFH.

View Article and Find Full Text PDF

2-Propanol Suspension Method to Increase Acetylcholinesterase and Flow Stability on μPADs.

ACS Appl Bio Mater

January 2025

Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628, Japan.

Ensuring detection performance and shelf life is crucial for analytical devices. Advances in materials and reaction mechanisms have improved detection performance, yet extending the operational lifetime of microfluidic paper-based analytical devices (μPADs)─especially those reliant on sensitive enzymes─remains a challenge. Here, we present an alternative to air-drying and lyophilization: loading enzymes suspended in 2-propanol (iPrOH).

View Article and Find Full Text PDF

The eyes are easily stimulated by external factors, which can cause inflammation. Anti-inflammatory drugs are usually used to inhibit the production of inflammatory factors. Many nonsteroidal anti-inflammatory drugs have been used for the eye, but due to the poor solubility of meloxicam, there are currently no marketed meloxicam preparations for the treatment of eye diseases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!