Binocular vision adaptively suppresses delayed monocular signals.

Neuroimage

Department of Psychology, The University of York, Heslington, York, United Kingdom.

Published: May 2018

A neutral density filter placed before one eye will produce a dichoptic imbalance in luminance, which attenuates responses to visual stimuli and lags neural signals from retina to cortex in the filtered eye. When stimuli are presented to both the filtered and unfiltered eye (i.e., binocularly), neural responses show little attenuation and no lag compared with their baseline counterpart. This suggests that binocular visual mechanisms must suppress the attenuated and delayed input from the filtered eye; however, the mechanisms involved remain unclear. Here, we used a Steady-State Visual Evoked Potential (SSVEP) technique to measure neural responses to monocularly and binocularly presented stimuli while observers wore an ND filter in front of their dominant eye. These data were well-described by a binocular summation model, which received the sinusoidal contrast modulation of the stimulus as input. We incorporated the influence of the ND filter with an impulse response function, which adjusted the input magnitude and phase in a biophysically plausible manner. The model captured the increase in attenuation and lag of neural signals for stimuli presented to the filtered eye as a function of filter strength, while also generating the filter phase-invariant responses from binocular presentation for EEG and psychophysical data. These results clarify how binocular visual mechanisms-specifically interocular suppression-can suppress the delayed and attenuated signals from the filtered eye and maintain normal neural signals under imbalanced luminance conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2018.02.021DOI Listing

Publication Analysis

Top Keywords

filtered eye
16
neural signals
12
stimuli presented
8
presented filtered
8
neural responses
8
attenuation lag
8
binocular visual
8
eye
7
binocular
5
signals
5

Similar Publications

To compare the long-term efficacy and safety of intense pulsed light (IPL) treatments using a 590-nm and an acne filter. In this prospective, randomized, paired-eye trial study, 30 patients with moderate and severe meibomian gland dysfunction (MGD) were followed up for at least one month after their last treatment. Group A received IPL treatment with an acne filter, a type of notch filter that blocks wavelengths between 600 and 800 nm, allowing IPL to emit wavelengths between 400-600 nm and 800-1200 nm.

View Article and Find Full Text PDF

Understanding Cyclists' Visual Behavior Using Eye-Tracking Technology: A Systematic Review.

Sensors (Basel)

December 2024

Department of Civil Engineering and Architecture, University of Catania, 64 Santa Sofia Street, 95123 Catania, Italy.

Eye-tracking technologies are emerging in research aiming to understand the visual behavior of cyclists to improve their safety. These technologies gather real-time information to reveal what the cyclists look at and how they respond at a specific location and time. This systematic review investigates the use of eye-tracking systems to improve cyclist safety.

View Article and Find Full Text PDF

There is a growing interest in harnessing natural compounds and bioactive phytochemicals to accelerate drug discovery and development, including in the treatment of human cancers. Receptor tyrosine kinases (RTKs) are critical regulators of many fundamental cellular processes and have been implicated in cancer pathogenesis as well as targets for anticancer drug development. The members of TAM, Tyro3, Axl, and MERTK subfamily RTKs, especially Mer, affect immune homeostasis in the tumor microenvironment.

View Article and Find Full Text PDF

Descemet's membrane (DM) detachment is a significant, if rare, risk of intracameral injection of viscoelastic to treat hypotony after glaucoma filtration surgery. We describe two cases of DM detachment following inadvertent injection of viscoelastic into the posterior stroma and the techniques used for their repair. In both cases, conventional air tamponade failed to resolve the detachment, and further surgical intervention was required.

View Article and Find Full Text PDF

Background: Modern reconstruction algorithms for computed tomography (CT) can exhibit nonlinear properties, including non-stationarity of noise and contrast dependence of both noise and spatial resolution. Model observers have been recommended as a tool for the task-based assessment of image quality (Samei E et al., Med Phys.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!