Widespread use of incorrect PCR ramp rate negatively impacts multidrug-resistant tuberculosis diagnosis (MTBDRplus).

Sci Rep

DST/NRF Centre of Excellence for Biomedical Tuberculosis Research, SA MRC Centre for Tuberculosis Research, Division of Molecular Biology and Human Genetics, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.

Published: February 2018

The scale-up of rapid drug resistance testing for TB is a global priority. MTBDRplus is a WHO-endorsed multidrug-resistant (MDR)-TB PCR assay with suboptimal sensitivities and high indeterminate rates on smear-negative specimens. We hypothesised that widespread use of incorrect thermocycler ramp rate (speed of temperature change between cycles) impacts performance. A global sample of 72 laboratories was surveyed. We tested 107 sputa from Xpert MTB/RIF-positive patients and, separately, dilution series of bacilli, both at the manufacturer-recommended ramp rate (2.2 °C/s) and the most frequently reported incorrect ramp rate (4.0 °C/s). Mycobacterium tuberculosis-complex DNA (TUB-band)-detection, indeterminate results, accuracy, and inter-reader variability (dilution series only) were compared. 32 respondents did a median (IQR) of 41 (20-150) assays monthly. 78% used an incorrect ramp rate. On smear-negative sputa, 2.2 °C/s vs. 4.0 °C/s improved TUB-band positivity (42/55 vs. 32/55; p = 0.042) and indeterminate rates (1/42 vs. 5/32; p = 0.039). The actionable results (not TUB-negative or indeterminate; 41/55 vs. 28/55) hence improved by 21% (95% CI: 9-35%). Widespread use of incorrect ramp rate contributes to suboptimal MTBDRplus performance on smear-negative specimens and hence limits clinical utility. The number of diagnoses (and thus the number of smear-negative patients in whom DST is possible) will improve substantially after ramp rate correction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5816666PMC
http://dx.doi.org/10.1038/s41598-018-21458-yDOI Listing

Publication Analysis

Top Keywords

ramp rate
28
widespread incorrect
12
incorrect ramp
12
indeterminate rates
8
smear-negative specimens
8
dilution series
8
ramp
7
rate
7
incorrect pcr
4
pcr ramp
4

Similar Publications

Introduction: The linear and continuous increase in power output (PO) during ramp incremental (RI) exercise causes a distinct V̇O2/PO relationship compared to constant work rate (CWR) exercise. Current methods enabling a translation of ramp-derived PO to CWR PO assume a linear development of the CWR V̇O2/PO relationship in the heavy-intensity domain. This study aimed to model the RI versus CWR V̇O2/PO relationship to investigate whether the loss of mechanical efficiency above GET develops linearly.

View Article and Find Full Text PDF

Partially temporally constrained modeling of speeding crash-injury severities on freeways and non-freeways before, during, and after the stay-at-home order.

Accid Anal Prev

January 2025

USDOT Center for Advanced Multimodal Mobility Solutions and Education, United States; Department of Civil and Environmental Engineering, University of North Carolina at Charlotte, United States. Electronic address:

Speeding crashes remain high injury severities after the stay-at-home order in California, highlighting a need for further investigation into the fundamental cause of this increment. To systematically explore the temporal impacts of the stay-at-home order on speeding behaviors and the corresponding crash-injury outcomes, this study utilizes California-reported single-vehicle speeding crashes on freeways (access-controlled) and non-freeways (non-access-controlled) before, during, and after the order. Significant injury factors and in-depth heterogeneity across observations are identified by random parameter logit models with heterogeneity in means and variances.

View Article and Find Full Text PDF

To define training zones, ventilatory thresholds (VTs) are commonly established by cardiopulmonary gas-exchange analysis during incremental exercise tests. Portable near-infrared spectroscopy (NIRS) devices have emerged as a potential tool for detecting these thresholds by monitoring muscle oxygenation. This study evaluated the accuracy of NIRS measurements to determine VTs or critical power (CP) based on muscle oxygen saturation and assesses the device's consistency across 2 constant-load tests.

View Article and Find Full Text PDF

Does a priming warm-up influence the incidence of [Formula: see text] during a ramp test and verification phase?

PLoS One

January 2025

Center for Research and Education in Special Environments, Department of Exercise and Nutrition Sciences, University at Buffalo, Buffalo, NY, United States of America.

Objective: This study compared the effects of two different warm-up protocols (normal vs. priming) on the oxygen plateau ([Formula: see text]) incidence rate during a ramp test. It also compared the cardiopulmonary responses during the ramp test and subsequent verification phase.

View Article and Find Full Text PDF

Even though venetoclax in combination with azacitidine (VenAza) is considered a low-intensity regimen, its patients present a high incidence of cytopenia and infections during the first courses, making the initial management a challenging phase. This difficulty in our center led to the establishment of an At-Home (AH) program for ramp-up and follow-up patients during the VenAza combination induction phase focused on therapy administration, patient and caregiver education, and management of adverse events (AEs). A total of 70 patients with newly diagnosed acute myeloid leukemia (ND-AML) or relapsed/refractory AML (R/R AML) were treated with VenAza from March 2019 to May 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?