Purpose: Posterior capsule opacification (PCO) still represents the main long-term complication of cataract surgery. Research into pharmacologic PCO prophylaxis is extensive. One promising candidate drug is methotrexate (MTX). Our aim is to determine the in vitro feasibility of MTX-loaded poly(lactic-co-glycolic) (PLGA) biomatrices sprayed on intraocular lenses (IOLs) as a drug-delivery implant.

Methods: Hydrophilic and hydrophobic acrylic IOLs were spray-coated with MTX-loaded PLGA. Unsprayed, solvent only, and solvent-PLGA-sprayed IOLs served as controls. All IOLs were evaluated for their growth-inhibiting properties in an in vitro anterior segment model and the ex vivo human capsular bag. The release kinetics of MTX from the IOLs was determined. The toxicity of MTX on corneal endothelial cells was evaluated by using a dye reduction colorimetric assay. MTX was also used in a scratch assay.

Results: MTX-PLGA-IOL showed a significant difference in cell proliferation and migration compared with all controls in the anterior segment model (p < 0.001) and in the human capsular bag model (p = 0.04). No difference in viability was observed on corneal endothelial cells (p = 0.43; p = 0.61). MTX significantly inhibited cells in the scratch assay (p = 0.02). At all measured points, the released MTX dose remained above EC50 and below the toxic dose for the endothelium.

Conclusions: In view of the strong inhibition of PCO in vitro with the lack of toxic effects on a corneal cell line, MTX encapsulating microspheres seem to be a promising method for modifying IOL.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2018.1437455DOI Listing

Publication Analysis

Top Keywords

intraocular lenses
8
posterior capsule
8
capsule opacification
8
anterior segment
8
segment model
8
iols
5
polylactic-co-glycolic acid
4
acid slow-release
4
slow-release drug-carrying
4
drug-carrying matrix
4

Similar Publications

Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis.

Int Ophthalmol

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, No.1, Dong Jiao Min Xiang, Dong Cheng District, Beijing, 100730, China.

Purpose: To compare the accuracy of intraocular lens (IOL) power calculation formulas in cataract patients with keratoconus (KC).

Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analysis statementand and was registered on PROSPERO (CRD42024568997). Pubmed, Web of Science, Cochrane Library, and EMBASE were searched for retrospective and prospective clinical studies published until October 2024.

View Article and Find Full Text PDF

Purpose: To describe a three-phase surgical approach for managing progressive visual decline in a patient with myopia magna and a history of epikeratophakia.

Methods: A 55-year-old woman with previous epikeratophakia surgery in both eyes experienced progressive visual deterioration. The three-phase approach included: (1) removal of the epikeratophakia lenticule, (2) cataract extraction with intraocular lens implantation, and (3) transepithelial topography-guided photorefractive keratectomy (trans-PRK).

View Article and Find Full Text PDF

Purpose: To compare the refractive accuracy of the Barrett True axial length (BTAL) formula, newly integrated into ARGOS, with that of the Barrett Universal II (BUII) formula calculated using axial length (AL) from IOL Master 700.

Setting: Private clinics in Kanagawa, Japan.

Design: Retrospective observational study.

View Article and Find Full Text PDF

Objectives: The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures.

Methods: We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ -10D) and super-high myopia groups (< -10D).

View Article and Find Full Text PDF

Purpose: To evaluate the symptoms, etiology and treatment of patient dissatisfaction after extended depth-of-focus (EDOF) intraocular lens (IOL) implantation.

Setting: University Eye Clinic, Maastricht University Medical Center, the Netherlands.

Design: Retrospective case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!