A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Custom Triflange Acetabular Components for Large Acetabular Defects: Minimum 10-Year Follow-up. | LitMetric

Compromise of bony support presents a difficult problem in acetabular revision surgery. Although various methods have been proposed to cope with this problem, they have had variable results and little long-term follow-up. The authors reviewed the results of 37 patients undergoing custom triflange revision surgery. Two patients were lost to follow-up, leaving 35 patients with minimum 10-year clinical and radiographic follow-up. Thirty-two (91%) of 35 components were unrevised and functioning well at minimum 10-year follow-up. One component placed for pelvic discontinuity loosened at 12 years after surgery but was converted to a conventional total hip. One component had failure of 3 ischial screws at 6 months; however, at 11 years, the patient had no additional clinical or radiographic evidence of loosening. The average Harris hip score was 28 preoperatively and 90 postoperatively. Two components (6%) were removed for infection. There were no dislocations, fractures, or nerve injuries. Revision of large acetabular defects with a custom triflange component resulted in reliably good to excellent results at minimum 10-year follow-up. [Orthopedics. 2018; 41(3):e316-e320.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20180213-11DOI Listing

Publication Analysis

Top Keywords

minimum 10-year
16
custom triflange
12
10-year follow-up
12
large acetabular
8
acetabular defects
8
revision surgery
8
clinical radiographic
8
follow-up
6
acetabular
4
triflange acetabular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!