WC based alloy coatings included different mass percent of Co and Cr have been synthesized on high carbon steel by using a facile high velocity oxy-fuel spray method. The mechanical nature of the coating films has been investigated by micro vickers hardness and fracture toughness. X-ray diffraction (XRD) and EDX analyses indicate that the three different samples (WC-10Co-4Cr, WC-17Co, and WC-12Co) consist of pure WC, W, Cr, and Co constituents as well as W2C and Co6W6C phases. The SEM and image analysis results show that WC-10Co-4Cr condition has higher porosity than those of WC-17Co, and WC-12Co coatings. WC-17Co coating showed the highest value in the hardness and fracture toughness test among three different samples. The obtained results revealed that the mechanical properties of WC based alloy coatings synthesized by a facile high velocity oxy-fuel spray method is very sensitive to Co content.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2018.14974DOI Listing

Publication Analysis

Top Keywords

alloy coatings
12
high velocity
12
velocity oxy-fuel
12
oxy-fuel spray
12
based alloy
8
facile high
8
spray method
8
hardness fracture
8
fracture toughness
8
three samples
8

Similar Publications

Background: For patients with osteoporosis and rotator cuff tears, there is still no consensus on current treatment methods. The material, structure, and number of anchors have important effects on the repair outcome.

Purpose: To investigate the use of chitosan quaternary ammonium salt-coated nickel-titanium memory alloy (NTMA) anchors to treat rotator cuff injury in shoulders with osteoporosis in a rabbit osteoporosis model.

View Article and Find Full Text PDF

Hydroxyapatite (HA) is an engineered biomaterial that closely resembles the hard tissue composition of humans. Biological HA is commonly non-stoichiometric and features lower crystallinity and higher solubility than stoichiometric HA. The chemical compositions of these biomaterials include calcium (Ca), phosphorus (P), and trace amounts of various ions such as magnesium (Mg), zinc (Zn), and strontium (Sr).

View Article and Find Full Text PDF

Periprosthetic joint infection (PJI) is a leading cause and major complication of joint replacement failure. As opposed to standard-of-care systemic antibiotic prophylaxis for PJI, we developed and tested titanium femoral intramedullary implants with titania nanotubes (TNTs) coated with the antibiotic gentamicin and slow-release agent chitosan through electrophoretic deposition (EPD) in a mouse model of PJI. We hypothesized that these implants would enable local gentamicin delivery to the implant surface and surgical site, effectively preventing bacterial colonization.

View Article and Find Full Text PDF

Multifunctional aluminum alloy slippery liquid-infused surface with porous and boehmite nanoflower structure.

J Colloid Interface Sci

December 2024

Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China; State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China. Electronic address:

The depletion of lubricants in (slippery liquid-infused porous surfaces) SLIPS poses a significant challenge to their long-term functionality. While line-shaped rough structures can mitigate lubricant loss to some extent, they often fail to provide the stability required for sustained performance. In this study, we present a novel porous nanoflower aluminum alloy slippery liquid-infused surface (P-NF-AA SLIPS), which integrates a porous framework with a rough nanoflower structure.

View Article and Find Full Text PDF

Inspired by the fundamental attribute of chirality in nature, chiral-engineered biomaterials now represent a groundbreaking frontier in biomedical fields. However, the integration of chirality within inorganic materials remains a critical challenge and developments of chirality-induced bionic bone implants are still in infancy. In this view, novel chiral hydroxyapatite (CHA) coated Ti alloys are successfully synthesized by a sophisticated chiral molecule-induced self-assembly method for the first time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!