A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionnl9f369pg82nvvbg6o905rp3toul1k73): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application and evaluation of a high-resolution mass spectrometry screening method for veterinary drug residues in incurred fish and imported aquaculture samples. | LitMetric

AI Article Synopsis

  • The paper discusses a new method for detecting veterinary drug residues in various fish species using liquid chromatography high-resolution mass spectrometry (LC-HRMS).
  • The LC-HRMS approach allows for the simultaneous monitoring of a wider variety of compounds compared to traditional methods, enhancing food safety analysis.
  • The study successfully identified several known and new drug residues in both aquacultured and imported fish, including compounds like amoxicillin diketone and ofloxacin.

Article Abstract

The ability to detect chemical contaminants, including veterinary drug residues in animal products such as fish, is an important example of food safety analysis. In this paper, a liquid chromatography high-resolution mass spectrometry (LC-HRMS) screening method using a quadrupole-Orbitrap instrument was applied to the analysis of veterinary drug residues in incurred tissues from aquacultured channel catfish, rainbow trout, and Atlantic salmon and imported aquacultured products including European eel, yellow croaker, and tilapia. Compared to traditional MS methods, the use of HRMS with nontargeted data acquisition and exact mass measurement capability greatly increased the scope of compounds that could be monitored simultaneously. The fish samples were prepared for analysis using a simple efficient procedure that consisted of an acidic acetonitrile extraction followed by solid phase extraction cleanup. Two different HRMS acquisition programs were used to analyze the fish extracts. This method detected and identified veterinary drugs including quinolones, fluoroquinolones, avermectins, dyes, and aminopenicillins at residue levels in fish that had been dosed with those compounds. A metabolite of amoxicillin, amoxicillin diketone, was also found at high levels in catfish, trout, and salmon. The method was also used to characterize drug residues in imported fish. In addition to confirming findings of fluoroquinolone and sulfonamide residues that were found by traditional targeted MS methods, several new compounds including 2-amino mebendazole in eel and ofloxacin in croaker were detected and identified. Graphical Abstract Aquacultured samples are analyzed with a high-resolution mass spectrometry screening method to detect and identify unusual veterinary drug residues including ofloxacin in an imported fish.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6434687PMC
http://dx.doi.org/10.1007/s00216-018-0917-xDOI Listing

Publication Analysis

Top Keywords

drug residues
20
veterinary drug
16
high-resolution mass
12
mass spectrometry
12
screening method
12
spectrometry screening
8
residues incurred
8
detected identified
8
imported fish
8
fish
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!