Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Mechanical thrombectomy (MT) has been widely accepted as a safe and effective treatment for acute ischemic stroke (AIS). Development of stent retriever devices has been intensively developed over the past two decades. In this study, we compared the effectiveness and safety of a new thrombectomy device with Solitaire FR for the treatment of AIS models.
Methods: Mechanical performance of stent retrievers was tested in vitro. Thrombin-induced thrombus was pre-injected into the right distal external carotid-maxillary artery in 18 dogs to create an acute thrombus occlusion model, and these animals were divided into a Tonbridge group (n=9, with Tonbridge stent Tonbridge Medical Technology) and a Solitaire group as control (n=9, with Solitaire stent, ev3 Neurovascular). Final flow restoration, side branches, recanalization time, distal vessel embolism, and device-related complications were recorded and compared. A post-procedure angiogram was obtained at 30 and 90 days after thrombectomy. Device manipulation-related damage to the arterial walls was evaluated histologically.
Results: In vitro test showed that the maximum friction within the microcatheter was 0.763 for the Tonbridge device and 0.784 n for the Solitaire (P>0.05). Slight increase in radial force was noticed for the Tonbridge (0.035 N/mm vs 0.031 N/mm of Solitaire, P>0.05). Eighteen and 16 retriever attempts were done in the Tonbridge (mean 2.0 attempts) and the Solitaire (mean 1.8 attempts) groups (P=0.74). The Tonbridge device led to good flow restoration in all nine (100%) models compared with eight (88.9%) in the Solitaire group (P=0.30). Side branches' influence (P=0.39), distal thromboembolism (P=0.60), and device-related complications (P=1.00) found no difference between the two groups. The rates of disruption of the internal elastic lamina (IEL) were 8.3% (2/24) and 4.2% (1/24) of the specimens, respectively (P=0.683). TICI 2b/3 flow of the right CCA were similar between the two groups at 1 (6/6 vs 6/6) and 3 months (6/6 vs 6/6) follow-up (P>0.05).
Conclusion: Our preliminary study indicated this new device was technically feasible and effective to be used in thrombectomy for the treatment of acute thrombus occlusion in canine models.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/neurintsurg-2017-013673 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!