Background: Accurate measurement of esophageal pressure (Pes) depends on proper filling of the balloon. Esophageal wall elastance (Ees) may also influence the measurement. We examined the estimation of balloon-surrounding elastance in a bench model and investigated a simplified calibrating procedure of Pes in a balloon with relatively small volume.

Methods: The Cooper balloon catheter (geometric volume of 2.8 ml) was used in the present study. The balloon was progressively inflated in different gas-tight glass chambers with different inner volumes. Chamber elastance was measured by the fitting of chamber pressure and balloon volume. Balloon pressure-volume (P-V) curves were obtained, and the slope of the intermediate linear section was defined as the estimated chamber elastance. Balloon volume tests were also performed in 40 patients under controlled ventilation. The slope of the intermediate linear section on the end-expiratory esophageal P-V curve was calculated as the Ees. The balloon volume with the largest Pes tidal swing was defined as the best volume. Pressure generated by the esophageal wall during balloon inflation (Pew) was estimated as the product of Ees and best volume. Because the clinical intermediate linear section enclosed filling volume of 0.6 to 1.4 ml in each of the patient, we simplified the estimation of Ees by only using parameters at these two filling volumes.

Results: In the bench experiment, bias (lower and upper limits of agreement) was 0.5 (0.2 to 0.8) cmHO/ml between the estimated and measured chamber elastance. The intermediate linear section on the clinical and bench P-V curves resembled each other. Median (interquartile range) Ees was 3.3 (2.5-4.1) cmHO/ml. Clinical best volume was 1.0 (0.8-1.2) ml and ranged from 0.6 to 1.4 ml. Estimated Pew at the best volume was 2.8 (2.5-3.5) cmHO with a maximum value of 5.2 cmHO. Compared with the conventional method, bias (lower and upper limits of agreement) of Ees estimated by the simple method was - 0.1 (- 0.7 to 0.6) cmHO/ml.

Conclusions: The slope of the intermediate linear section on the balloon P-V curve correlated with the balloon-surrounding elastance. The estimation of Ees and calibration of Pes were feasible for a small-volume-balloon.

Trial Registration: Identifier NCT02976844 . Retrospectively registered on 29 November 2016.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5813414PMC
http://dx.doi.org/10.1186/s12871-018-0488-6DOI Listing

Publication Analysis

Top Keywords

intermediate linear
20
best volume
16
esophageal wall
12
chamber elastance
12
balloon volume
12
slope intermediate
12
balloon
10
volume
9
balloon pressure-volume
8
wall elastance
8

Similar Publications

Colloids can be used either as model systems for directed assembly or as the necessary building blocks for making functional materials. Previous work primarily focused on assembling colloids under a single external field, where controlling particle-particle interactions is limited. This work presents results under a combination of electric and magnetic fields.

View Article and Find Full Text PDF

The HNH endonuclease domain of the giant virus MutS7 specifically binds to branched DNA structures with single-stranded regions.

DNA Repair (Amst)

December 2024

Agriculture and Marine Science Program, Graduate School of Integrated Arts and Science, Kochi University, Nankoku, Kochi 783-8502, Japan; Agricultural Science, Graduate School of Integrated Arts and Science, Kochi University, Nankoku, Kochi 783-8502, Japan. Electronic address:

Most giant viruses including Mimiviridae family build large viral factories within the host cytoplasms. These giant viruses are presumed to possess specific genes that enable the rapid and massive replication of their large double-stranded DNA genomes within viral factories. It has been revealed that a functionally uncharacterized protein, MutS7, is expressed during the operational phase of the viral factory.

View Article and Find Full Text PDF

Background: Erectile dysfunction (ED) is considered the tip of the iceberg for cardiovascular disease (CVD). However, there is still conflicting evidence regarding their relationship. Recently, a validated tool for the Atherosclerotic Cardiovascular Disease (ASCVD) risk score has provided a key opportunity to delve deeper into the relationship between ED and CVD.

View Article and Find Full Text PDF

Multienzyme Cascade Catalyzed Skeleton Rearrangement in a Caged Polyketide Biosynthesis.

Org Lett

December 2024

State Key Laboratory of Chemical Biology, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences (CAS), CAS, Shanghai 200032, China.

Rearrangement of the skeleton is crucial for improving the structural complexity and diversity of type II polyketide natural products. In this study, we investigated the rearrangement process from a planar aromatic tetracyclic intermediate to the caged lactones, which is managed by five oxidoreductases. We chemically synthesized the proposed linear tetracyclic substrate, validated the transformation process through and experiments, and elucidated the enzyme-catalyzed mechanism using isotope labeling.

View Article and Find Full Text PDF

Imaged capillary isoelectric focusing was successfully applied for separating an in-house synthesized closely related peptide pair, that is, a linear 12-mer (Rp5-L) and its cyclic 15-mer variant (Rp5-C). Rp5-L represents a mimotope, that is, an epitope mimicking peptide, of the CD20 antigen, which is over-expressed in B-cell-related tumors. Peptide identity-including the successful disulfide bond formation in Rp5-C-was confirmed with matrix-assisted laser desorption ionization-time of flight mass spectrometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!