This study aims to investigate pre-clinical esophageal involvement in systemic sclerosis (SSc) by high-resolution impedance manometry (HRiM), its associations with disease features including lung involvement, and its predictivity of esophageal symptoms overtime. Charts of 45 asymptomatic (no heartburn/regurgitation/dysphagia) SSc patients (96% females; mean age 46 years) with at least one follow-up (FU) visit and complete clinical, serological, functional, and radiological assessment, including high-resolution computed tomography (HRCT) of the chest and lung function tests, that had undergone esophageal HRiM were retrospectively evaluated. Esophagogastric junction-contractile integral (EGJ-CI) and esophageal body motility, as evaluated by mean distal contractile integral (DCI), were assessed. SSc patients had a normal esophageal motility in 7/45 cases, a defective EGJ-CI in 28, an ineffective esophageal motility (IEM) in 17, and aperistalsis in 12. Defective EGJ-CI was associated with IEM/aperistalsis in 20 cases, while 9 patients had isolated IEM. Defective EGJ-CI and/or IEM/aperistalsis were associated with a diffusing lung capacity for CO < 80% of predicted value (all p < 0.05), while defective EGJ-CI was also associated with interstitial lung disease on HRCT (p = 0.03). Prevalence of any HRiM abnormality was higher in anti-centromere antibody negative patients (all p < 0.05). IEM/aperistalsis independently increased the risk of esophageal symptoms by 2.3-fold (95% CI 1.1-5.7) and was associated with their higher cumulative incidence with respect to patients with other HRiM patterns at FU (χ = 4.63; p = 0.03). SSc patients asymptomatic for esophageal involvement can have HRiM abnormalities in up to 84% of cases. A baseline-impaired motility is a risk factor for symptomatic esophageal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10067-018-4026-1DOI Listing

Publication Analysis

Top Keywords

defective egj-ci
12
high-resolution impedance
8
impedance manometry
8
systemic sclerosis
8
associations disease
8
disease features
8
ssc patients
8
esophageal motility
8
esophageal
7
esophageal high-resolution
4

Similar Publications

Background: At present, there are few studies related to mean nocturnal baseline impedance (MNBI), esophageal dynamic reflux monitoring, high-resolution esophageal manometry (HRM) parameter indexes, and its diagnostic value in gastroesophageal reflux disease (GERD).

Objective: To analyze the factors influencing MNBI and examine the diagnostic value of MNBI in GERD.

Methods: A retrospective analysis on 434 patients with typical reflux symptoms who underwent gastroscopy, 24-hour multichannel intraluminal impedance and pH monitoring (MII/pH) and HRM.

View Article and Find Full Text PDF

Background: Gastroesophageal reflux disease (GERD) pathophysiology is multifactorial. Greater importance has been attributed to a defective lower esophageal sphincter (LES) in comparison to an altered transdiaphragmatic pressure gradient (TPG). This study aims to evaluate the role of the TPG and LES disfunction in GERD pathogenesis.

View Article and Find Full Text PDF

Objectives: Esophagogastric junction contractile integral (EGJ-CI) is a novel indicator to evaluate quantitatively the esophagogastric junction (EGJ) barrier function. We aimed to assess the role of EGJ-CI in patients with refractory gastroesophageal reflux disease (GERD) symptoms and the correlation between EGJ-CI and impedance-pH monitoring characteristics.

Methods: In total 82 patients with proton pump inhibitors (PPIs)-refractory gastroesophageal reflux symptoms (heartburn or regurgitation) were enrolled.

View Article and Find Full Text PDF

Gastroesophageal reflux disease (GERD) is a common condition characterized by troublesome symptoms or esophageal mucosal lesions attributed to excessive esophageal acid exposure. Various pathophysiological mechanisms account for GERD, including impaired esophageal peristalsis and anatomical or physiological defects at the esophagogastric junction (EGJ). Endoscopy identifies GERD complications and detects potential alternative diagnoses.

View Article and Find Full Text PDF

This study aims to investigate pre-clinical esophageal involvement in systemic sclerosis (SSc) by high-resolution impedance manometry (HRiM), its associations with disease features including lung involvement, and its predictivity of esophageal symptoms overtime. Charts of 45 asymptomatic (no heartburn/regurgitation/dysphagia) SSc patients (96% females; mean age 46 years) with at least one follow-up (FU) visit and complete clinical, serological, functional, and radiological assessment, including high-resolution computed tomography (HRCT) of the chest and lung function tests, that had undergone esophageal HRiM were retrospectively evaluated. Esophagogastric junction-contractile integral (EGJ-CI) and esophageal body motility, as evaluated by mean distal contractile integral (DCI), were assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!