This review compares and discusses conventional versus miniaturized specimen preparation methods for transmission electron microscopy (TEM). The progress brought by direct electron detector cameras, software developments and automation have transformed transmission cryo-electron microscopy (cryo-EM) and made it an invaluable high-resolution structural analysis tool. In contrast, EM specimen preparation has seen very little progress in the last decades and is now one of the main bottlenecks in cryo-EM. Here, we discuss the challenges faced by specimen preparation for single particle EM, highlight current developments, and show the opportunities resulting from the advanced miniaturized and microfluidic sample grid preparation methods described, such as visual proteomics and time-resolved cryo-EM studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/pmic.201700176 | DOI Listing |
J Dent (Shiraz)
December 2024
Postgraduate Student, Dept. of Operative Dentistry, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
Statement Of The Problem: Dentin adhesion is challenging and needs modifications. Newly introduced nature-derived materials may be a useful solution in improving dentin adhesion. The use of natural antimicrobial agents for pretreating prepared dentin surfaces before restoration has become of interest.
View Article and Find Full Text PDFCureus
November 2024
Biochemistry, North Eastern Indira Gandhi Regional Institute of Health and Medical Sciences, Shillong, IND.
Background: Laparoscopic cholecystectomy (LC) is currently the gold standard of care for managing gallstone disease. The time taken to perform LC depends on both patient-related and surgeon-related factors. Recognizing factors associated with difficult LC (DLC) can aid in appropriate surgeon selection and judicious scheduling of cases.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Electronic address:
Statement Of Problem: Three-dimensional (3D) printing and milling technologies have been increasingly used in prosthodontic practice for fabricating digital prostheses. Nevertheless, evidence relating to the wear resistance of denture teeth fabricated using these methods is lacking.
Purpose: The purpose of this in vitro study was to compare the wear resistance exhibited by denture teeth fabricated using 3D printing and milling technologies with prefabricated denture teeth.
BMC Oral Health
December 2024
Dental Sciences Research Center, Department of Prosthodontics, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Int J Prosthodont
December 2024
Purpose: This study aimed to evaluate the hydrolytic behavior of different computer-aided design/computer-aided manufacturing (CAD/CAM) resin matrix ceramics (RMCs) in different food-simulating liquids (FSLs).
Materials And Methods: Five different CAD/CAM blocks, one from polymer-infiltrated ceramic networks (PICNs; Vita Enamic (EN)) and four from resin-based composites (RBCs; Lava Ultimate (UL), Cerasmart (CER), Brilliant Crios (BR), and Block HC (HC)) were selected. Forty specimens were prepared for each material, and they randomly distributed to each FSLs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!