Purpose: The synergistic effects of a trunk orthosis and an ankle-foot orthosis (AFO) in stroke patients with a hemiplegic gait are unclear. We previously developed a trunk orthosis with joints providing resistive force (TORF) to modify malalignment of the trunk and pelvis and confirmed its positive effects in stroke patients during level walking without an AFO. The aim of the present study was to determine if this trunk orthosis and an AFO have synergistic effects during level walking in community-dwelling patients with chronic stroke.
Methods: Twenty-eight community-dwelling stroke patients performed level walking at a self-selected speed with an AFO and again while wearing a TORF (TORF group) or a corset (control group). Spatiotemporal, kinematic, and kinetic data were recorded using a three-dimensional motion analysis system.
Results: When compared with the control group, the TORF group showed significant increases in walking speed, number of steps on the paretic leg per minute, and peak ankle plantar flexion moment during the single stance phase.
Conclusion: The TORF increased the ankle joint plantar flexion moment at the end of the single stance phase during level walking in stroke patients, leading to an increase in their gait speed because of the modified trunk and pelvis alignment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804285 | PMC |
http://dx.doi.org/10.2147/CIA.S146881 | DOI Listing |
Bioengineering (Basel)
December 2024
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.
Background: Orthotic treatment is a well-acknowledged conservative treatment for moderate adolescent idiopathic scoliosis (AIS). The efficacy of this treatment is significantly determined by the forces applied to the bodies of patients. However, there is uncertainty regarding the optimal force levels that should be applied to the patient's torso by spinal orthosis.
View Article and Find Full Text PDFProsthet Orthot Int
December 2024
Department of Physiotherapy and Rehabilitation Faculty of Health Sciences, Gazi University, Ankara, Turkey.
Background: The dynamic elastomeric fabric orthoses (DEFOs) are made of neoprene material, providing the right biomechanical alignment and afferent input in the trunk, pelvis, and extremities, potentially allowing individuals to actively participate in daily life.
Objective: The aim of this study was to investigate the effects of DEFOs applied to the lower trunk and pelvis, on balance, gait parameters, and pelvic symmetry in children with cerebral palsy (CP).
Study Design: An evaluator-blinded randomized controlled trial.
J Orthop Case Rep
December 2024
Department of Orthopedic Surgery, Sapporo Medical University, School of Medicine, Sapporo, Japan.
Introduction: Few studies have reported the treatment and rehabilitation of combined fractures of the femur, tibia, and ankle in the same lower limb.
Case Report: A 69-year-old man presented to our hospital with a fall injury due to high-energy trauma after falling from a 5 m ladder while painting and landing on both feet. Examination revealed right femoral supracondylar; left tibial plateau; right calcaneal; left ankle crush; first and third lumbar vertebrae burst; sacral; C7, Th1, and Th9 compression; and bilateral acetabular fractures.
J Bodyw Mov Ther
October 2024
Faculty of Health Science Technology, HRH Princess Chulabhorn College of Medical Science, Chulabhorn Royal Academy, Bangkok, Thailand. Electronic address:
Introduction: Sedentary lifestyles is linked to a reduction in back muscle strength, endurance, and balance, consequently increasing the risk of experiencing low back pain. Kinesio taping has been shown to be effective in enhancing endurance, flexibility, and balance. This study aimed to investigate the effects of Kinesio taping on measures of lumbar function in sedentary individuals.
View Article and Find Full Text PDFJ Bodyw Mov Ther
October 2024
Concordia University, St. Paul, USA.
Introduction: The purpose of this study was to investigate the effects of Kinesio® tape on scapulothoracic joint kinematics during humerothoracic elevation and lowering in asymptomatic participants.
Method: Sixteen males and 24 females participated in data collection using the Polhemus G4 3D electromagnetic motion capture system. Dominant shoulder kinematics were collected while the participant performed three repetitions of elevation in the frontal, sagittal, and scapular planes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!