Acquired ventricular septal defect due to infective endocarditis.

Ann Pediatr Cardiol

Department of Pediatrics, Division of Pediatric Cardiology, The University of Iowa Stead Family Children's Hospital, lowa, USA.

Published: January 2018

Acquired intracardiac left-to-right shunts are rare occurrences. Chest trauma and myocardial infection are well-known causes of acquired ventricular septal defect (VSD). There have been several case reports describing left ventricle to right atrium shunt after infective endocarditis (IE). We present here a patient found to have an acquired VSD secondary to IE of the aortic and tricuspid valves in the setting of a known bicuspid aortic valve. This is the first case reported of acquired VSD in a pediatric patient in the setting of IE along with literature review of acquired left-to-right shunts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5803962PMC
http://dx.doi.org/10.4103/apc.APC_130_17DOI Listing

Publication Analysis

Top Keywords

acquired ventricular
8
ventricular septal
8
septal defect
8
infective endocarditis
8
left-to-right shunts
8
acquired vsd
8
acquired
6
defect infective
4
endocarditis acquired
4
acquired intracardiac
4

Similar Publications

Repeatability of radiomic features in myocardial T1 and T2 mapping.

Eur Radiol

January 2025

Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Centre Rostock, Rostock, Germany.

Purpose: To investigate the test-retest repeatability of radiomic features in myocardial native T1 and T2 mapping.

Methods: In this prospective study, 50 healthy volunteers (29 women and 21 men, mean age 39.4 ± 13.

View Article and Find Full Text PDF

Objective And Rationale: Small studies have shown that the QT interval follows a circadian rhythm. This finding has never been confirmed in a large real-world hospital population and the clinical meaning of disrupted rhythmicity remains unknown.

Methods: In this cohort study, all consecutive adult patients with at least one 12-lead ECG acquired between 1991 and 2021 were considered.

View Article and Find Full Text PDF

Deep Neural Network Analysis of the 12-Lead Electrocardiogram Distinguishes Patients With Congenital Long QT Syndrome From Patients With Acquired QT Prolongation.

Mayo Clin Proc

January 2025

Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Mayo Clinic, Rochester, MN; Department of Molecular Pharmacology and Experimental Therapeutics, Windland Smith Rice Sudden Death Genomics Laboratory, Mayo Clinic, Rochester, MN; Division of Heart Rhythm Services, Department of Cardiovascular Medicine, Windland Smith Rice Genetic Heart Rhythm Clinic, Mayo Clinic, Rochester, MN. Electronic address:

Objective: To test whether an artificial intelligence (AI) deep neural network (DNN)-derived analysis of the 12-lead electrocardiogram (ECG) can distinguish patients with long QT syndrome (LQTS) from those with acquired QT prolongation.

Methods: The study cohort included all patients with genetically confirmed LQTS evaluated in the Windland Smith Rice Genetic Heart Rhythm Clinic and controls from Mayo Clinic's ECG data vault comprising more than 2.5 million patients.

View Article and Find Full Text PDF

Background: Cardiovascular disease (CVD) remains the leading cause of death in pregnant and peripartal women in western countries. Physiological changes during pregnancy can lead to cardiovascular complications in the mother; women with pre-existing heart disease may not tolerate these changes well, increasing their susceptibility to adverse cardiovascular outcomes during pregnancy. The aim of this study is to characterize pregnancy-induced changes in cardiac function, biomarker concentrations and cardiovascular outcomes in women with CVD during pregnancy at a tertiary care hospital in Germany.

View Article and Find Full Text PDF

Background: Clinical brain MRI scans, including contrast-enhanced (CE-MR) images, represent an underutilized resource for neuroscience research due to technical heterogeneity.

Purpose: To evaluate the reliability of morphometric measurements from CE-MR scans compared to non-contrast MR (NC-MR) scans in normal individuals.

Methods: T1-weighted CE-MR and NC-MR scans from 59 normal participants (aged 21-73 years) were compared using CAT12 and SynthSeg+ segmentation tools.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?