Characteristics of Single-Loop Macroreentrant Biatrial Tachycardia Diagnosed by Ultrahigh-Resolution Mapping System.

Circ Arrhythm Electrophysiol

From the Department of Cardiac Electrophysiology, Service de Rythmologie, Hôpital Cardiologique du Haut-Lévêque (Centre Hospitalier Universitaire de Bordeaux), Avenue de Magellan, 33604, Bordeaux-Pessac, France (T.K., R.M., A. Denis, M.T., A.F., N.T., G.M., G.C., M.W., K.V., C.A.M., N.A.J., J.D., N.K., T.P., F.S., H.C., M. Hocini, M. Haïssaguerre, P.J., N.D.); and Unité INSERM U1048, University Hospital Rangueil, Toulouse, France (A. Duparc, A.R., P.M.).

Published: February 2018

Background: Biatrial tachycardia (BiAT) is a rare form of atrial macroreentrant tachycardia, in which both atria form a critical part of the circuit. We aimed to identify the characteristics and precise circuits of single-loop macroreentrant BiATs.

Methods And Results: We identified 8 patients (median age, 59.5 years old) with 9 BiATs in a cohort of 336 consecutive patients from 2 institutions who had undergone AT catheter ablation using an automatic ultrahigh-resolution mapping system. Seven of the 8 patients had a history of persistent AF ablation, including septal or anterior left atrium ablation before developing BiAT. One of the 8 patients had a history of an atrial septal patch closure with a massively enlarged right atrium. Nine ATs (median cycle length, 334 ms; median 12 561 points in the left atrium; 8814 points in the right atrium) were diagnosed as single-loop macroreentrant BiATs. We observed 3 types of BiAT (1) BiAT with a perimitral and peritricuspid reentrant circuit (n=3), (2) BiAT using the right atrium septum and a perimitral circuit (n=3), and (3) BiAT using only the left atrium and right atrium septum (n=3). Catheter ablation successfully terminated 8 of the 9 BiATs.

Conclusions: All patients who developed BiAT had an electric obstacle on the anteroseptal left atrium, primarily from prior ablation lesions. In this situation, mapping of both atria should be considered during AT. Because 3 types of single-loop BiAT were observed, ablation strategies should be adjusted to the type of BiAT circuit.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.117.005558DOI Listing

Publication Analysis

Top Keywords

left atrium
16
single-loop macroreentrant
12
biat
9
biatrial tachycardia
8
ultrahigh-resolution mapping
8
mapping system
8
catheter ablation
8
patients history
8
atrium
8
circuit n=3
8

Similar Publications

Introduction: Complete radical resection is crucial for successfully treating thymic carcinomas. However, when the invasion of the great vessels or the heart in Masaoka III and IV stages occurs, the management poses more challenges. The R0 resection often requires neoadjuvant treatment.

View Article and Find Full Text PDF

Left atrial shunting devices: why, what, how, and… when?

Heart Fail Rev

January 2025

Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, Milan, Italy.

Left atrial (LA) hypertension is central in the pathophysiology of heart failure (HF) in general and of HF with preserved ejection fraction (HFpEF) in particular. Despite approved treatments, a number of HF patients continue experiencing disabling symptoms due to LA hypertension, causing pulmonary congestion, pulmonary hypertension, and right heart dysfunction, at rest and/or during exercise. LA decompression therapies, i.

View Article and Find Full Text PDF

Atrial fibrillation versus. atrial myopathy in thrombogenesis: Two sides of the same coin?

Trends Cardiovasc Med

January 2025

Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart and Chest Hospital, Liverpool, United Kingdom; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark; Medical University of Bialystok, Bialystok, Poland.

Atrial fibrillation (AF) and atrial myopathy are recognized contributors to cardiovascular morbidity, particularly ischemic stroke. AF poses an elevated risk of thrombogenesis due to irregular heart rhythm leading to blood stasis and clot formation. Atrial myopathy, marked by structural and functional alterations in the atria, is emerging as a crucial factor influencing thromboembolic events, independently of AF.

View Article and Find Full Text PDF

Glucagon can increase the force of contraction (FOC) in, for example, canine hearts. Currently, whether glucagon can also increase the FOC via cAMP-increasing receptors in the human atrium is controversial discussed. Glucagon alone did not (up to 1 µM) raise the FOC in human right atrial preparations (HAP).

View Article and Find Full Text PDF

Pharmacokinetics of Hydrogen During Hydrogen-Saturated Saline Infusion in Pigs.

Biomedicines

January 2025

Department of Medicine and Clinical Science, Graduate School of Medicine, Yamaguchi University, Ube 755-8505, Japan.

: Hydrogen gas (H) has been shown to be effective in the treatment of various clinical conditions, from acute illnesses to chronic illnesses. However, its clinical indications and the corresponding appropriate hydrogen delivery methods have yet to be determined. This is due to the fact that the pharmacokinetics and pharmacodynamics of hydrogen in each delivery method have not been experimentally proven.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!