Objectives: To compare the duration to establish an umbilical venous catheter and an intraosseous access in real hospital delivery rooms and as a secondary aim to assess delaying factors during establishment and to provide recommendations to accelerate vascular access in neonatal resuscitation.

Design: Retrospective analysis of audio-video recorded neonatal simulation training.

Settings: Simulation training events in exact replications of actual delivery/resuscitation rooms of 16 hospitals with different levels of care (Austria and Germany). Equipment was prepared the same way as for real clinical events.

Subjects: Medical teams of four to five persons with birth-related background (midwives, nurses, neonatologists, and anesthesiologists) in a realistic team composition.

Interventions: Audio-video recorded mannequin-based simulated resuscitation of an asphyxiated newborn including the establishment of either umbilical venous catheter or intraosseous access.

Measurements And Main Results: The duration of access establishment (time from decision to first flush/aspiration), preparation (decision to start of procedure), and the procedure itself (start to first flush/aspiration) was significantly longer for umbilical venous catheter than for intraosseous access (overall duration 199 vs 86 s). Delaying factors for umbilical venous catheter establishment were mainly due to the complex approach itself, the multitude of equipment required, and uncertainties about necessary hygiene standards. Challenges in intraosseous access establishment were handling of the unfamiliar material and absence of an intraosseous access kit in the resuscitation room. There was no significant difference between the required duration for access establishment between large centers and small hospitals, but a trend was observed that duration for umbilical venous catheter was longer in small hospitals than in centers. Duration for intraosseous access was similar in both hospital types.

Conclusions: Vascular access establishment in neonatal resuscitation could be accelerated by infrastructural improvements and specific training of medical teams. In simulated in situ neonatal resuscitation, intraosseous access is faster to establish than umbilical venous catheter. Future studies are required to assess efficacy and safety of both approaches in real resuscitation settings.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PCC.0000000000001508DOI Listing

Publication Analysis

Top Keywords

umbilical venous
24
venous catheter
24
intraosseous access
24
access establishment
16
vascular access
12
neonatal resuscitation
12
catheter intraosseous
12
access
11
duration establish
8
establish umbilical
8

Similar Publications

Mesenchymal stem cell therapy as a game-changer in liver diseases: review of current clinical trials.

Stem Cell Res Ther

January 2025

School of Medical Laboratory Science and Biotechnology, College of Medical Science and Technology, Taipei Medical University, 10F., Teaching & Research Building, Shuang-Ho Campus, No. 301, Yuantong Rd., Zhonghe Dist., Taipei, 235, Taiwan.

Chronic liver diseases, including cirrhosis and liver failure, remain formidable challenges due to their complex progression and limited therapeutic options. Mesenchymal stem cell (MSC) therapy has emerged as a game-changing approach, leveraging its potent immunomodulatory, anti-fibrotic, and regenerative capabilities, along with the ability to transdifferentiate into hepatocytes. This review delves into the latest advances in MSC-based treatments for chronic and end-stage liver diseases, as highlighted in current clinical trials.

View Article and Find Full Text PDF

Introduction: Excess weight during pregnancy is a condition that can affect both mother and fetus, through the maternal-fetal interface, which is constituted by the placenta and umbilical cord. The umbilical vein is responsible for transporting oxygen and nutrients to the fetus, and its proper functioning depends on the integrity of its structure. The remodeling of the umbilical vein represents one of the causes of inadequate transport of nutrients to the fetus, being potentially harmful.

View Article and Find Full Text PDF

Previous studies highlighting the pivotal function of the S100A8 protein have shown that inflammation and vascular endothelial harm play a major role in deep vein thrombosis (DVT) development, as evidenced by earlier studies highlighting the pivotal function of the S100 calcium-binding protein A8 (S100A8). Therefore, we aimed to establish a connection between S100A8 and DVT and investigate the role of S100A8 in DVT development. Blood specimens were taken from 23 patients with DVT and 31 controls.

View Article and Find Full Text PDF

Size-dependent Nanoparticle Accumulation In Venous Malformations.

J Vasc Anom (Phila)

December 2024

Laboratory for Biomaterials and Drug Delivery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts.

Objective: The current treatment of venous malformations (VMs) consists of medications with systemic toxicity and procedural interventions with high technical difficulty and risk of hemorrhage. Using nanoparticles (NPs) to enhance drug delivery to VMs could enhance efficacy and decrease systemic toxicity. NPs can accumulate in tissues with abnormal vasculature, a concept known as the enhanced permeation and retention (EPR) effect.

View Article and Find Full Text PDF

Introduction: ICAM-1 is an adhesion molecule expressed on the endothelial cells and is involved in regulating leukocyte recruitment to the site of inflammation. Elevated ICAM-1 mRNA expression was found in the serum of mothers with chorioamnionitis. This study aimed to determine the expression of ICAM-1 in the placenta and umbilical cord of pregnancy with chorioamnionitis, and its association with adverse neonatal outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!