Background: The aim of this study was to evaluate and compare relatively less explored fragment reattachment methods following traumatic injury.
Materials And Methods: Eighty sound permanent maxillary incisors were selected and mounted in acrylic blocks. Teeth were sectioned using the diamond disc and randomly divided into 4 groups ( = 20), Group A, B, C, D. In Group A, after reattachment with composite, a 1 mm-depth circumferential chamfer was placed in the fracture line using a diamond disc bur and filled with composite. In Group B, two vertical grooves 1 mm deep, 1 mm wide, and 4 mm length were placed on the labial surface perpendicular to the fracture line and filled with two fiber-reinforced composite (FRC) posts and composite. In Group C, dentin is removed from the fragment and filled with composite. In Group D, the teeth were intact which served as control group. The force required to fracture the reattached teeth were recorded in Newton's using an onscreen calibration tool of the universal testing machine.
Results: Teeth in Groups A, B, C required lesser force to fracture when compared with the teeth of the Group D. When compared to Group D, Group A showed a fracture resistance of 36%, Group B 62%, and Group C 32%.
Conclusion: This study proves that reattachment by vertical grooves with FRC posts showed highest fracture resistance and it is the most preferred method. So far no attempt has been made to reattach fractured fragment using vertical grooves and reinforcing with FRC posts.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5799998 | PMC |
http://dx.doi.org/10.4103/JCD.JCD_144_17 | DOI Listing |
Indian J Ophthalmol
December 2024
Cornea, Cataract and Refractive Surgery Services, Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Intrascleral haptic fixation of intraocular lens (IOL) is an extremely useful technique to provide visual rehabilitation in eyes with inadequate capsular support. It requires exteriorization of haptics along with tucking of haptics in the scleral groove preferably and conventionally in the horizontal meridian. In eyes with large corneal diameter, there is difficulty in tucking enough length of the haptics into the intrascleral groove, carrying the risk of slippage of haptics and decentration of IOL.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
School of Architecture and Civil Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Screw-groove piles, a new type of precast pile, are economically and environmentally friendly and improve the load-bearing performance of piles through a unique screw-groove structure. To reveal the load-transfer characteristics and bearing mechanism of the screw-groove pile, the axial force, load-settlement curve, skin friction, bearing capacity, and response characteristics of the foundation for piles under vertical loading were analyzed. Furthermore, a parameter analysis of the ultimate bearing capacity and material utilization of screw-groove piles was performed using the finite element method.
View Article and Find Full Text PDFJTCVS Tech
December 2024
Department of Thoracic and Cardiovascular Surgery, Sejong General Hospital, Bucheon-si, Gyeonggi-do, South Korea.
Objective: Minimally invasive repair using robotic systems has been accepted as an attractive alternative in the surgical repair of atrial septal defects (ASDs). Clear exposure of the entire rim of the ASD is often hindered during a robotic approach. Here, we describe an approach using vertical right atriotomy along the interatrial groove that may enhance the exposure of the ASD.
View Article and Find Full Text PDFDrug Deliv Transl Res
December 2024
Department of Bioscience and Bioinformatics, Kyushu Institute of Technology, 680-4 Kawazu, Iizuka, Fukuoka, 820-8502, Japan.
Langmuir
December 2024
GRASP, Institute of Physics B5a, University of Liège, Liège B4000, Belgium.
We investigate herein the impact of helical structures on the motion of asymmetrical droplets along vertically twisted fibers. The droplet adopts helical motion around the bundle driven by gravity. This complex motion can be manipulated by varying the twists turns of the fibers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!