Stereotactic body radiotherapy (SBRT) for spine tumors has demonstrated clinical effectiveness. The treatment planning and delivery techniques have evolved from dynamic conformal arc therapy, to fixed gantry angle intensity modulated radiotherapy (IMRT), and most recently to volumetric modulated arc therapy (VMAT). A hybrid-arc (HARC) planning and delivery method combining dynamic conformal arc therapy delivery with a number of equally spaced IMRT beams is proposed. In this study we investigated plan quality, delivery accuracy, and efficiency of 3 delivery techniques: IMRT, HARC, and VMAT. Patients who underwent spine SBRT treatments were randomly selected from an Institutional Review Board-approved registry. For each patient, the prescription dose was 14 to 16 Gy in a single fraction to cover >90% of the tumor (without planning margin) while constraining V ≤ 10% of the spinal cord and the maximum point dose (MPD) of the spinal cord ≤ 14 Gy. All cases were clinically treated with fixed gantry step-shoot IMRT plans and then re-planned with VMAT using Pinnacle 9.0 and with HARC using Brainlab iPlan 4.5. Student t-test was used to compare the dosimetric end points, including V to the planning target volume, homogeneity index, MPD, the conformity index, V of the spinal cord, and MPD. To compare the accuracy of delivery, we delivered all plans on a phantom and conducted gamma index (GI) comparisons with 3 mm/3% and 2 mm/2% criteria. All plans met our clinical requirements. Among 3 techniques, there were no differences on dose coverage to the tumor volume, maximum dose to the spinal cord, and plan homogeneity index (p > 0.05). The average V of the spinal cord was 6.66 ± 0.03%, 5.49 ± 0.03%, and 4.76 ± 0.02% for IMRT, HARC, and VMAT plans, respectively. Accordingly, the conformity indices were 1.30 ± 0.11 and 1.29 ± 0.20, 1.53 ± 0.29, respectively. VMAT plans were significantly (p < 0.05) less conformal but significantly (p < 0.05) lower V of the spinal cord than those from HARC and IMRT plans. With delivery accuracy measured by GIs, the average GIs of 3%/3 mm were 92.6 ± 1.1%, 96.5 ± 2.7%, 99.0 ± 1.1% for IMRT, HARC, and VMAT plans, respectively. The differences were significant (p < 0.05). Accordingly, the average monitor units were 9238 ± 2242, 9853 ± 2548 and 5091 ± 910. The plan quality created from the 3 planning techniques can meet the clinical requirement. Adding arc beams in delivery such as in HARC and VMAT plans improves the delivery accuracy. VMAT is the most efficient delivery method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2017.12.009DOI Listing

Publication Analysis

Top Keywords

spinal cord
16
arc therapy
12
plan quality
8
delivery
8
quality delivery
8
delivery accuracy
8
stereotactic body
8
body radiotherapy
8
spine tumors
8
planning delivery
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!