Measurement of Carpal Alignment Indices Using 3-Dimensional Computed Tomography.

J Hand Surg Am

Department of Orthopaedic Surgery, Inje University, Ilsan Paik Hospital, Gyeonggi-do, Korea. Electronic address:

Published: August 2018

Purpose: This study aimed to establish normal values for wrist carpal alignment measured by 3-dimensional computed tomography (CT) and to show the inter- and intraobserver reliability of this measurement compared with simple radiography.

Methods: The study utilized 3-dimensional CT and simple radiography of wrist joints in 30 asymptomatic volunteers. The wrist position was standardized using a custom-designed positioning device. Three independent observers measured carpal alignment parameters including distal radius articular angle, radiolunate angle, radioscaphoid angle, radiocapitate angle, radius-third metacarpal angle, scapholunate angle, lunocapitate angle, and lunate-third metacarpal angle.

Results: Based on 3-dimensional CT measurement, the mean values of these parameters were: 12.9° ± 1.8° for the distal radius articular angle; 1.2° ± 3.8° for the radiolunate angle; 54.2° ± 5.6° for the radioscaphoid angle; 1.9° ± 2.2° for the radiocapitate angle; -1.0° ± 2.5° for the radius-third metacarpal angle; 52.9° ± 6.9° for the scapholunate angle; 0.7° ± 4.1° for the lunocapitate angle; -2.3° ± 4.6° for the lunate-third metacarpal angle. All parameters showed high inter- and intraobserver reliability in the 2 modalities.

Conclusions: The normal values and ranges for carpal alignment angles were evaluated by using 3-dimensional CT. We could obtain high reliability in 3-dimensional CT as well as plain radiograph for the measurement of carpal alignment.

Type Of Study/level Of Evidence: Diagnostic II.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2018.01.003DOI Listing

Publication Analysis

Top Keywords

carpal alignment
16
angle
15
metacarpal angle
12
measurement carpal
8
3-dimensional computed
8
computed tomography
8
normal values
8
inter- intraobserver
8
intraobserver reliability
8
distal radius
8

Similar Publications

Carpometacarpal (CMC) joint fractures-dislocations are rare due to the complex structure of the carpal bones and strong ligamentous support; while the clinical image is usually "noisy," they present significant management challenges due to the unstable nature of the injury. These injuries are typically caused by high-energy trauma and frequently result in dorsal dislocations. Treatment requires a careful balance between the immobilization and surgical restoration of the anatomical alignment to prevent complications.

View Article and Find Full Text PDF

Introduction: Perilunate dislocations (PLD) and perilunate fracture-dislocations (PLFD) are high-energy wrist injuries often linked to significant post-traumatic osteoarthritis. This study aims to determine whether PLD and PLFD yield different radiological outcomes following surgical treatment while identifying prognostic factors for worse outcomes.

Materials And Methods: We retrospectively analyzed 51 patients treated for perilunate injuries between 2000 and 2022.

View Article and Find Full Text PDF

Traditionally, patients with a fracture of the distal radius are treated in a cast if they do not require surgery. If the fracture requires manipulation, the cast is moulded to hold the reduction and maintain normal anatomical alignment during healing. However, is a cast necessary for patients whose fracture does not require manipulation? Removable splints are an alternative treatment option.

View Article and Find Full Text PDF

Patient-specific scaphoid prosthesis: surgical technique.

Arch Orthop Trauma Surg

December 2024

Biomedical Engineering and Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.

The scaphoid bone is essential for wrist stability, force transmission, and movement, being crucial for maintaining carpal kinematics. In cases where the scaphoid is non-reconstructable, a complete replacement can serve as a treatment option to preserve carpal alignment and motion. This approach has evolved since its first descriptions in 1945, benefiting significantly from advancements in patient-specific implant design, additive manufacturing/3D printing, and material use in recent years.

View Article and Find Full Text PDF

Background: Scaphoid nonunion often requires surgical management involving the combination of a bone graft and internal fixation to restore the carpal alignment and length. While traditionally, the scaphoid waist nonunions have been treated with open bone grafts, with the advent of arthroscopy, bone graft reconstruction can now be carried out as an arthroscopic assisted minimally invasive procedure. We aimed to compare outcomes between open and arthroscopic bone grafting in the treatment of scaphoid nonunion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!