Arthrodesis of the first tarsal metatarsal joint can be accomplished in many ways. The compressive force attained between various constructs remains unclear. This study compares compression achieved through a locking/compression Lapidus plate both with and without the addition of a lag screw. A dorsal medial Lapidus/locking compression plate (Total Compression Plate System, OrthoPro, Salt Lake City, UT, now Wright Medical) was applied to one cadaveric limb, while the same plate with the addition of a 4.0-mm cannulated lag screw was applied to the contralateral limb for a total of 5 matched pairs of cadaveric specimens. Compressive force was recorded over time and compared between the constructs using a compression sensor (8" FlexiForce Resistive Force Sensor, Phidgets Inc, Calgary, Alberta, Canada). Compression was maintained for 45.4 minutes in the plate only construct, and 317 minutes with the addition of the lag screw ( = .010). The mean time to 50% peak compression for the plate only construct was 4.90 minutes compared with 15.11 minutes for plate with lag screw construct (P = .012). The addition of a lag screw is recommended for extending the length of compression and possibly reducing nonweightbearing time and the risk of nonunion. Level V.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1938640018758374DOI Listing

Publication Analysis

Top Keywords

lag screw
24
addition lag
12
compression plate
12
plate
9
plate lag
8
compression
8
compressive force
8
plate addition
8
minutes plate
8
plate construct
8

Similar Publications

Background: Multiple approaches exist for operative fixation of metacarpal fractures; with common treatments including lag screw fixation or open-reduction internal fixation (ORIF) with plates and screws. Recently, the adaptation of intramedullary screw (IMS) placement has allowed for an essentially closed approach with stable fixation and theoretically improved outcomes. Thus, we sought to compare such approaches to ultimately determine the superior method for achieving the goal of return to normal function.

View Article and Find Full Text PDF

Orthopedic implant infections are rare but represent a significant problem for patients, surgeons, and the healthcare systems. This is because these infections cause severe and persistent pain and, in some cases, may require revision of the implant, among other things. Thus, there is strong interest in the use of antimicrobial coatings on orthopedic implants.

View Article and Find Full Text PDF

This study compares the compression force of cortical screws used in lag fashion with partially threaded cannulated screws and fully threaded headless cannulated screws as fixation methods for humeral condylar fractures in dogs. Cadavers of eleven dogs weighing an average of 10.99 ± 2.

View Article and Find Full Text PDF

Background And Objectives: Bennett fractures are intra-articular fractures of the first metacarpal, typically resulting from axial loading. The optimal surgical method for fixation remains a topic of ongoing debate. This study aims to evaluate and compare the biomechanical properties of different fixation techniques.

View Article and Find Full Text PDF

Objective: To compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly.

Methods: A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!