Objectives: In order to assess short-term exposure to peracetic acid (PAA) in disinfection processes, the Authors compared 4 industrial hygiene monitoring methods to evaluate their proficiency in measuring airborne PAA concentrations.

Material And Methods: An active sampling by basic silica gel impregnated with methyl p-tolyl sulfoxide (MTSO), a passive solid phase micro-extraction technique using methyl p-tolyl sulfide (MTS) as on-fiber derivatization reagent, an electrochemical direct-reading PAA monitor, and a novel visual test strip PAA detector doped with 2,2'-azino-bis (3-ethylbenzothiazoline)-6-sulfonate were evaluated and tested over the range of 0.06-16 mg/m3, using dynamically generated PAA air concentrations.

Results: The linear regression analysis of linearity and accuracy showed that the 4 methods were suitable for PAA monitoring. Peracetic acid monitoring in several use applications showed that the PAA concentration (1.8 mg/m3) was immediately dangerous to life or health as proposed by the National Institute of Occupational Safety and Health, and was frequently exceeded in wastewater treatment (up to 7.33 mg/m3), and sometimes during food and beverage processes and hospital high-level disinfection operations (up to 6.8 mg/m3).

Conclusions: The methods were suitable for the quick assessment of acute exposure in PAA environmental monitoring and can assist in improving safety and air quality in the workplace where this disinfectant is used. These monitoring methods allowed the evaluation of changes to work out practices to reduce PAA vapor concentrations during the operations when workers are potentially overexposed to this strong antioxidant agent. Int J Occup Med Environ Health 2018;31(4):527-535.

Download full-text PDF

Source
http://dx.doi.org/10.13075/ijomeh.1896.01166DOI Listing

Publication Analysis

Top Keywords

peracetic acid
12
paa
9
monitoring methods
8
methyl p-tolyl
8
methods suitable
8
monitoring
5
methods
5
assessment occupational
4
occupational exposure
4
exposure gaseous
4

Similar Publications

Background: The use of laryngeal masks (LM) has increased widely today, both in anesthesia and in emergency cases. LM are available as reusable and disposable. Although reuse of disposable LM is not recommended, they are reused again after decontamination with different methods in anesthesia units in some countries.

View Article and Find Full Text PDF

Klebsiella pneumoniae is an opportunistic pathogen responsible for various infections in humans and animals. It is known for its resistance to multiple antibiotics, particularly through the production of Extended-Spectrum Beta-Lactamases (ESBLs), and its ability to form biofilms that further complicate treatment. This study aimed to isolate and identify K.

View Article and Find Full Text PDF

Moderate preoxidation is feasible for odor-producing algae treatments, usually requiring trade-offs in algal removal and integrity maintenance. However, dosing oxidants may cause internal oxidative homeostasis imbalances and secondary odorous metabolite responses, adding new trade-offs for moderate treatments. Peracetic acid (PAA)/Fe processes are promising strategies in moderate treatments and thus were applied to examine how to achieve the following three trade-offs: good algal removal, no odorant increases and no releases.

View Article and Find Full Text PDF

Control of rotavirus by sequential stress of disinfectants and gamma irradiation in leafy vegetable industry.

Food Res Int

January 2025

Department of Food Safety and Regulatory Science, Advanced Food Safety Research Group, Chung-Ang University, Anseong-si, Gyeonggi-do 17546, Republic of Korea. Electronic address:

Rotavirus (RV) causes severe gastroenteritis in infants and young children worldwide. Fresh produce has been reported as a source of RV infection during production and harvesting, leading to foodborne illness. Cases of contamination from contact surfaces have also been reported.

View Article and Find Full Text PDF

The sulfur-containing chemical warfare agents sulfur mustard HD and nerve agent VX are highly toxic and persistent in the environment. Therefore, their neutralisation requires harsh oxidation conditions, but also precise selectivity. Here we report the safe and effective detoxification of surrogates CEES and PhX by selective oxidation of the sulfur atom by generating peracetic acid from AcOEt and aq.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!