The triceps surae primarily acts as plantarflexor of the ankle joint. However, the group also causes inversion and eversion at the subtalar joint. Despite this, the Achilles tendon moment arm is generally measured without considering the potential influence of inversion/eversion of the foot during plantarflexion. This study investigated the effect of foot inversion and eversion on the plantarflexion Achilles tendon moment arm. Achilles tendon moment arms were determined using the centre-of-rotation method in magnetic resonance images of the left ankle of 11 participants. The foot was positioned at 15° dorsiflexion, 0° or 15° plantarflexion using a Styrofoam wedge. In each of these positions, the foot was either 10° inverted, neutral or 10° everted using an additional Styrofoam wedge. Achilles tendon moment arm in neutral foot position was 47.93 ± 4.54 mm and did not differ significantly when the foot was positioned in 10° inversion and 10° eversion. Hence, inversion/eversion position of the foot may not considerably affect the length of the Achilles tendon moment arm. This information could be useful in musculoskeletal models of the human lower leg and foot and when estimating Achilles tendon forces during plantarflexion with the foot positioned in inversion or eversion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5792916 | PMC |
http://dx.doi.org/10.1098/rsos.171358 | DOI Listing |
Acta Bioeng Biomech
September 2024
Jagiellonian University Medical College, Faculty of Medicine, Department of Bioinformatics and Telemedicine, Kraków, Poland.
The purpose was to answer what is the relationship between torques acting on the human body, how does the triceps calf muscle balance the weight of a tilted body and what is the foot's role in the titling body? Two research models were developed. Model 1 - the one-sided lever system consists of a flat bar with, an axis of rotation, used to determine the weight and torque at a given point on it. Model 2 - the two-sided lever system consists of a flat bar imitating a tilted body counteracted by the Achilles tendon, and a platform imitating a foot.
View Article and Find Full Text PDFJ Am Podiatr Med Assoc
January 2025
†Division of Geriatrics, Department of Internal Medicine, Marmara University Medical School, Pendik, Istanbul, Turkey.
This case report aims to demonstrate a rare occurrence of tendon rupture attributable to levofloxacin use in Helicobacter pylori eradication. On the seventh day of treatment, the patient experienced severe foot pain and difficulty in walking, leading to a diagnosis of Achilles tendon rupture confirmed through magnetic resonance imaging. Levofloxacin-induced tendinopathy and/or rupture are rare complications that are often linked to age and sex.
View Article and Find Full Text PDFEur J Phys Rehabil Med
January 2025
Division of Physical Medicine and Rehabilitation, Department of Surgical Sciences, University of Turin, Turin, Italy -
Background: The Achilles tendon is one of the most frequent sites of tendinopathy in both healthy and pathological subjects. An innovative approach for the quantitative assessment of the Achilles tendon structure, named Ultrasound Tissue Characterization (UTC), has recently been developed. However, no previous study performed the UTC-based assessment of the tendon structure in rheumatologic patients affected by insertional Achilles tendinopathy.
View Article and Find Full Text PDFCureus
December 2024
Department of Pediatric Surgery and Vascular Anomalies, Xi'an International Medical Center Hospital, Xi'an, CHN.
Purpose We aimed to report an innovative single-site endoscopic surgery for soft tissue lesions performed at our center. Methods All patients who underwent soft tissue surgery were reviewed. All consecutive patients who underwent single-site endoscopic surgery between September 2019 and March 2024 were included in the study.
View Article and Find Full Text PDFMater Today Bio
February 2025
Basic Research Key Laboratory of General Surgery for Digital Medicine, Affiliated Hospital of Hebei University, Baoding, 071000, China.
Achilles tendon is a motor organ that is prone to tissue adhesion during its repair process after rupture. Therefore, developing motion-responsive and anti-adhesive biomaterials is an important need for the repair of Achilles tendon rupture. Here, we report an injectable lubricative hydrogel (ILH) based on hydration lubrication mechanism, which is also motion-responsive based on sol-gel reversible transmission.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!