Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Synthetic hair-growth compounds have been illegally used in diverse products to enhance the short-term efficacy of these products. In this study, a rapid and simultaneous method for the determination of hair-growth compounds in adulterated products based on ultra high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed and validated. The limit of detection (LOD) and limit of quantitation (LOQs) of the method were 0.08-43.6ng/mL and 0.27-145ng/mL for the solid-, liquid-, and cream-type samples, respectively. Good calibration linearity for all compounds was demonstrated with a correlation coefficient (r) higher than 0.997. The intra- and inter-assay precisions were within 11%. The corresponding accuracies were 86-117% and 81-113%, respectively. The mean recoveries obtained for the solid-, liquid, and cream-type samples ranged from 87 to 114%, with a relative standard deviation (RSD) within 6%. The RSD of the stability evaluated at 4°C for 48h was less than 6%. The established method was used to screen 76 samples advertised as hair-growth treatments, from online and offline markets, over the course of two years. In 10% of the samples, four compounds, including triaminodil, minoxidil, finasteride, methyltestosterone, and testosterone-propionate were detected. The concentrations were in the range of 0.5-16.4mg/g. This technique provides a reliable platform for technical analysis for continuous monitoring of adulterated products to protect public health.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.forsciint.2017.12.042 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!