A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Transfusion reactions after transfusion of platelets stored in PAS-B, PAS-C, or plasma: a nationwide comparison. | LitMetric

Background: Platelets (PLTs) stored in PLT additive solution (PAS) are associated with fewer allergic reactions than plasma-stored PLTs. However, earlier studies could not provide conclusive evidence on febrile reactions and did not analyze other transfusion reactions separately due to limited sample size. We therefore compared incidences of all transfusion reactions of PAS-B-PLTs, PAS-C-PLTs, and plasma-PLTs.

Study Design And Methods: In this observational study, all transfusion reactions reported to the national hemovigilance office of the Netherlands from 2006 to 2015 were included.

Results: During the study period, a total of 2407 transfusion reactions after PLT transfusions were reported. In that period 553,267 pooled buffy coat-derived PLT units were issued, of which 83,884 were stored in PAS-B, 45,728 in PAS-C, and 423,655 in plasma. Regarding transfusion-related circulatory overload, transfusion-related acute lung injury, and "other reactions" no significant differences were observed between the PLT products. When PAS-B-PLT transfusions were compared to plasma-PLT transfusions, the overall relative risk (RR; 95% confidence interval [CI]) of transfusion reactions was 0.99 (0.88-1.11); for allergic and febrile nonhemolytic transfusion reactions (FNHTRs) it was 0.66 (0.55-0.80) and 1.54 (1.27-1.86), respectively. When PAS-C-PLTs were compared to plasma-PLTs, the RR (95% CI) was 0.56 (0.46-0.68) for all transfusion reactions, 0.38 (0.28-0.52) for allergic reactions, and 0.82 (0.59-1.13) for FNHTRs. When PAS-C-PLTs were compared to PAS-B-PLTs, for all reactions the RR (95% CI) was 0.56 (0.45-0.70) for allergic reactions 0.58 (0.40-0.82), and for FNHTRs 0.53 (0.37-0.75).

Conclusions: PAS-C-PLTs are associated with fewer transfusion reactions compared to plasma-PLTs and compared to PAS-B-PLTs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/trf.14509DOI Listing

Publication Analysis

Top Keywords

transfusion reactions
36
reactions
13
allergic reactions
12
transfusion
10
stored pas-b
8
associated fewer
8
pas-c-plts compared
8
compared plasma-plts
8
95% 056
8
compared pas-b-plts
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!