Recurrences are frequently observed after ventral hernia repair. Based on clinical data, the mesh-defect area ratio (MDAR) can lead to lower recurrence rates. Using dynamic intermittent strain (DIS) in a pig tissue model, MDAR can be modified to give a measure called grip to better assess the mechanical stability of ventral hernia repair. The focus of this experimental study is to assess the different aspects of mesh overlap (OL) and fixation only in bridging repair of ventral hernias. DIS mimics coughing actions in an model with the repetition of submaximal impacts delivered a hydraulically driven plastic containment. Tissue derived from pig bellies simulates a ventral hernia with varying defect sizes. MDAR is calculated from the hernia orifice and the mesh OL. Commercially available meshes were strengthened with glue, tacks, and sutures to bridge the defects. The reconstructions are strained with up to 425 dynamic impacts. The grip of each repair is assessed using MDAR modified by the strength of the fixation. The DIS classification is based on bridging of a 5 cm ventral hernia orifice with an OL of 5 cm in a sublay position. The classification discriminates meshes properties upon DIS strain. MDAR is calculated to be 9 under these conditions. Decreasing the OL or increasing the hernia orifice reduces MDAR to numbers below 9. MDAR is modified to reach GRIP. Closure of the peritoneum adds about 4 to the grip given by MDAR. The multiplying factor of a transmural suture or one tack of Securestrap or Protack is 0.5 times the number of tacks applied. The multiplier given by a bonding spot of Glubran is similar to that of an Absorbatack being 0.33. Plotting the likelihood of a bridging repair to survive more than 400 DIS impacts versus the grip estimated from the factors given above, the grip to be passed for a durable repair is 10 for Parietex Progrip, and Dynamesh Cicat and 25 for Dynamesh IPOM. Clinical data previously published can be reculculated to assess MDAR and permit an estimation of the grip of the reconstruction. In these recalculations, a correlation between MDAR and long-term recurrence rates is found. A dimensionless number called grip can be calculated. The grip can be modified by fixation in a reproducible way. A higher grip can improve the durability of ventral hernia repair. We believe that a higher grip leads to lower recurrence rates in the clinical setting.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5780431 | PMC |
http://dx.doi.org/10.3389/fsurg.2017.00078 | DOI Listing |
No Shinkei Geka
January 2025
Department of Neurosurgery, Yao Tokushukai General Hospital.
Full endoscopic spine surgery is a technique to perform hernia extraction using a single-hole-type endoscope with a coaxial operation system of a sheath, endoscope, and surgical instrument in reflux water. In the lumbar region, the ventral side of the dura mater can be directly approached via the lateral route. Not only is the skin incision small, but damage to muscle tissue is also minimal, which is why it is a minimally invasive surgery.
View Article and Find Full Text PDFRambam Maimonides Med J
January 2025
Associate Professor, Department of Surgery, Mata Gujri Memorial Medical College and LSK Hospital, Kishanganj, Bihar, India.
Surg Endosc
January 2025
Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.
Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.
View Article and Find Full Text PDFSci Rep
January 2025
Department of General Surgery, Shaoxing Central Hospital (The Central Affiliated Hospital, Shaoxing University), Shaoxing, 312030, Zhejiang Province, China.
Ventral hernias pose a prevalent challenge in abdominal wall surgery, with ongoing advancements in repair techniques designed to enhance patient outcomes. This study evaluates the efficacy, safety, and socio-economic impact of Totally Extraperitoneal Sublay Repair (TES) versus Laparoscopic Intraperitoneal Onlay Mesh Repair (IPOM) for small to medium-sized ventral hernias, with a particular focus on postoperative quality of life and patient satisfaction. A retrospective cohort study was conducted, encompassing 125 patients who underwent ventral hernia repair between May 2018 and November 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!