Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A sensitive, rapid, simple and economical ultra-performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) was developed and validated for simultaneous determination of imatinib, dasatinib and nilotinib in human plasma using gliquidone as internal standard (IS). Liquid-liquid extraction method with ethyl acetate was used for sample pre-treatment. The separation was performed on an Xtimate Phenyl column using isocratic mobile phase consisting of A (aqueous phase: 0.15% formic acid and 0.05% ammonium acetate) and B (organic phase: acetonitrile) (A:B=40:60, v/v). The flow rate was 0.25 mL/min and the total run time was 6 min. The multiple reaction monitoring (MRM) transitions, 494.5→394.5 for imatinib, 488.7→401.5 for dasatinib, 530.7→289.5 for nilotinib and 528.5→403.4 for IS, were chosen to achieve high selectivity in the simultaneous analyses. The method exhibited great improvement in sensitivity and good linearity over the concentration range of 2.6-5250.0 ng/mL for imatinib, 2.0-490.0 ng/mL for dasatinib, and 2.4-4700.0 ng/mL for nilotinib. The method showed acceptable results on sensitivity, specificity, recovery, precision, accuracy and stability tests. This UPLC-MS/MS assay was successfully used for human plasma samples analysis and no significant differences were found in imatinib steady-state trough concentrations among the -1889T>C or 699G>A genotypes (>0.05). This validated method can provide support for clinical therapeutic drug monitoring and pharmacokinetic investigations of these three tyrosine kinase inhibitors (TKIs).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790746 | PMC |
http://dx.doi.org/10.1016/j.jpha.2017.07.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!