O-(β-hydroxyethyl)rutosides determination by micellar flow injection (FI)-spectrofluorimetry.

J Pharm Anal

Instituto de Química de San Luis (INQUISAL-CONICET), 5700 San Luis, Argentina.

Published: December 2014

A simple, eco-friendly, sensitive and economic flow injection spectrofluorimetric method was developed for the determination of O-(β-hydroxyethyl)rutosides. The procedure was based on the use of an anionic surfactant such as sodium dodecyl sulfate to provide an appreciable O-(β-hydroxyethyl)rutosides fluorescence enhancement, increasing considerably the sensitivity of detection. All the variables affecting the fluorescence intensity were studied and optimized. The flow rate was 5 mL/min with detection at 450 nm (after excitation at 346 nm). A linear correlation between drug amount and peak area was established for O-(β-hydroxyethyl)rutosides in the range of 0.01-200 µg/mL with a detection limit of 0.001 µg/mL (/=3). Validation processes were performed by recovering studies with satisfactory results. The new methodology can be employed for the routine analysis of O-(β-hydroxyethyl)rutosides in bulks as well as in commercial formulations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5761362PMC
http://dx.doi.org/10.1016/j.jpha.2014.07.002DOI Listing

Publication Analysis

Top Keywords

flow injection
8
o-β-hydroxyethylrutosides
5
o-β-hydroxyethylrutosides determination
4
determination micellar
4
micellar flow
4
injection fi-spectrofluorimetry
4
fi-spectrofluorimetry simple
4
simple eco-friendly
4
eco-friendly sensitive
4
sensitive economic
4

Similar Publications

Background: Intravascular injection of liquid adhesive hemostats is a rare but serious complication that can result in cerebral thromboembolism.

Observations: A 64-year-old female underwent orbitozygomatic craniotomy for posterior communicating artery aneurysm clipping with the routine use of a flowable hemostatic agent during extradural dissection. After placement of the aneurysm clip, flow was confirmed through the parent vessel and nearby branches.

View Article and Find Full Text PDF

, a traditional Miao medicine, is commonly used by the renowned national-level Chinese Traditional Medicine practitioner Zhengshi Wu for the treatment of diarrhea due to its strong antioxidative, anti-inflammatory, and antidiarrheal effects. This study aimed to establish a high-performance liquid chromatography (HPLC) fingerprint for to provide new evidence and technical means for the scientific evaluation and effective quality control of . The procedure involved isolation with a Nano ChromCore C18 column (250 mm × 4.

View Article and Find Full Text PDF

RP-HPLC Method for Rhein Quantification in L. (Fabaceae) Leaves.

Acta Med Philipp

December 2024

Institute of Herbal Medicine, National Institutes of Health, University of the Philippines Manila.

Objectives: The aim of this study is to establish a Reversed Phase - High Performance Liquid Chromatographic (RP-HPLC) method for the quantification of Rhein from L. leaves.

Methods: A Shimadzu system equipped with a C18 Column (150 x 4.

View Article and Find Full Text PDF

Aim: To explore the neuroprotective effects of high mobility group box 2 () knockdown on retinal ganglion cells (RGCs) in the retinal ischemia-reperfusion injury (RIRI).

Methods: Oxygen-glucose deprivation (OGD)-injured RGCs from postnatal three-day C57BL/6 mice pups and high intraocular pressure (IOP)-induced RIRI mice were used as cellular and animal models of RIRI. The expression of HMGB2 in the retina of RIRI mice and OGD-injured RGCs was detected through reverse transcription-polymerase chain reaction (RT-qPCR) and Western blotting.

View Article and Find Full Text PDF

Removal of MTBE and BTEX Pollutants from Contaminated Water Using Colloidal Activated Carbon (CAC).

ACS Omega

January 2025

Groundwater Protection Unit, Environmental Department, Saudi Aramco, P.O. Box1977, Dhahran 31311, Saudi Arabia.

Methyl tertiary-butyl ether (MTBE) and BTEX (benzene, toluene, ethylbenzene, and xylenes) are common groundwater contaminants that pose significant health risks. This study investigated the efficiency of a colloidal activated carbon (CAC) material in removing MTBE and BTEX from contaminated water using batch and continuous core flooding systems. In the batch system, a mixture of sand and carbonate was coated with 1-3 g of CAC for the removal of contaminants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!