Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A simple, rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay method has been developed and fully validated for the simultaneous quantification of atorvastatin, metformin and glimepiride in human plasma. Carbamazepine was used as internal standard (IS). The analytes were extracted from 200 μL aliquots of human plasma via protein precipitation using acetonitrile. The reconstituted samples were chromatographed on a Alltima HP C18 column by using a 60:40 (v/v) mixture of acetonitrile and 10 mM ammonium acetate (pH 3.0) as the mobile phase at a flow rate of 1.1 mL/min. The calibration curves obtained were linear ( ≥0.99) over the concentration range of 0.50-150.03 ng/mL for atorvastatin, 12.14-1207.50 ng/mL for metformin and 4.98-494.29 ng/mL for glimepiride. The API-4000 LC-MS/MS in multiple reaction monitoring (MRM) mode was used for detection. The results of the intra- and inter-day precision and accuracy studies were well within the acceptable limits. All the analytes were found to be stable in a battery of stability studies. The method is precise and sensitive enough for its intended purpose. A run time of 2.5 min for each sample made it possible to analyze more than 300 plasma samples per day. The developed assay method was successfully applied to a pharmacokinetic study in human male volunteers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760920 | PMC |
http://dx.doi.org/10.1016/j.jpha.2012.09.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!