Prevention of cross contamination with active pharmaceutical ingredients is crucial and requires special attention in pharmaceutical industries. Current method validation describes the determination of Nabumetone (NAB) residue on a stainless steel surface using swab sampling with a sensitive HPLC-DAD analysis. The acceptance limit was decided as 2 μg swab per 100 cm. Cotton swabs impregnated with extraction solution were used to determine residual drug content. Recoveries were 90.88%, 91.42%, and 92. 21% with RSD ranging from 2.2% to 3.88% at three concentration levels. Residual concentration was found to be linear in the range of 0.1-4.56 μg/mL, when estimated using a Phenomenex Luna C (25 cm×5 μm×4.6 mm i.d.) column at 1.0 mL/min flow rate and 230 nm. The mobile phase consisted of a mixture of methanol:acetonitrile:water (55:30:15, v/v/v). The LOD and LOQ for NAB were found to be 0.05 and 0.16 μg/mL, respectively. The validated method was found to be simple, selective and sensitive for demonstration of cleaning validation of NAB residues on a stainless steel surface.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760904 | PMC |
http://dx.doi.org/10.1016/j.jpha.2012.04.003 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!