A simple, sensitive, and specific liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of desloratadine (DL) in human plasma using desloratadine-d5 (DLD5) as an internal standard (IS). Chromatographic separation was performed using an Xbridge C18 column (50 mm×4.6 mm, 5 μm) with an isocratic mobile phase composed of 10 mM ammonium formate: methanol (20:80, v/v), at a flow rate of 0.7 mL/min. DL and DLD5 were detected with proton adducts at / 311.2→259.2 and 316.2→264.3 in multiple reaction monitoring (MRM) positive modes, respectively. Liquid-liquid extraction (LLE) method was used to extract the drug and the IS. The method was validated over a linear concentration range of 5.0-5000.0 pg/mL with a correlation coefficient of ()≥0.9994. This method demonstrated intra- and inter-day precision within 0.7-2.0% and 0.7-2.7%, and an accuracy within 101.4-102.4%, and 99.5-104.8%. DL was found to be stable throughout the freeze-thaw cycles, bench-top, and postoperative stability studies. This method was successfully applied in the analysis of plasma samples following oral administration of DL (5 mg) in 35 healthy Indian male human volunteers under fasting conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5760887PMC
http://dx.doi.org/10.1016/j.jpha.2012.01.008DOI Listing

Publication Analysis

Top Keywords

quantification desloratadine
8
desloratadine human
8
human plasma
8
method
5
plasma lc-esi-ms/ms
4
lc-esi-ms/ms application
4
application pharmacokinetic
4
pharmacokinetic study
4
study simple
4
simple sensitive
4

Similar Publications

Two accurate, precise and robust multivariate chemometric methods were developed for the simultaneous determination of montelukast sodium (MON), rupatadine fumarate (RUP) and desloratadine (DES). These methods provide a cost-effective alternative to chromatographic techniques by utilizing spectrophotometry in pharmaceutical quality control. The proposed approaches, partial least squares-1 (PLS-1) and artificial neural network (ANN), were optimized using genetic algorithm (GA) to select the most influential wavelengths, enhancing model performance.

View Article and Find Full Text PDF

In the last few decades, green analytical chemistry (GAC) has become a smart magical solution for the qualification and quantification of many drugs. In the current study, a direct, sensitive, and green RP-HPLC method was used to separate three anti-histaminic combinations rupatadine/montelukast, desloratadine/montelukast, fexofenadine/montelukast, and finally a mixture of rupatadine and its metabolite; desloratadine in less than 20 min. The developed method was optimized by a 2 full factorial design to improve the chromatographic responses.

View Article and Find Full Text PDF

An accurate mass database and a method based on ultra high performance liquid chromatography-electrostatic field orbitrap high resolution mass spectrometry (UHPLC-Orbitrap HRMS) were developed. These were applied in the screening and identification of illegally added medicines in herbal tea. Based on investigations, 167 medicines were selected to build an accurate MS database; these medicines included antipyretic analgesics, glucocorticoids, antibiotics, and antihistamines, among other categories.

View Article and Find Full Text PDF

Environmentally-friendly technology for rapid identification and quantification of emerging pollutants from wastewater using infrared spectroscopy.

Environ Toxicol Pharmacol

November 2020

CEB - Centre of Biological Engineering, University of Minho, 4710-057, Braga, Portugal; Instituto Politécnico de Coimbra, ISEC, DEQB, Rua Pedro Nunes, Quinta da Nora, 3030-199 Coimbra, Portugal.

The monitoring of emerging pollutants in wastewaters is nowadays an issue of special concern, with the classical quantification methods being time and reagent consuming. In this sense, a FTIR transmission spectroscopy based chemometric methodology was developed for the determination of eight of these pollutants. A total of 456 samples were, therefore, obtained, from an activated sludge wastewater treatment process spiked with the studied pollutants, and analysed in the range of 200 cm to 14,000 cm.

View Article and Find Full Text PDF

An innovative high-performance liquid chromatography assay method was developed and validated for quantification of dextromethorphan hydrobromide and desloratadine simultaneously in monophasic liquid formulation by preparing syrup containing 30 mg/5 mL of dextromethorphan hydrobromide and 1.2 mg/mL of desloratadine. The chromatographic severance was executed by gradient solution A and B.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!