Purpose: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements.
Methods: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual's HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the 'average' HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data.
Results: The range of ICC for intra- and interobserver variability was 0.79-0.99 and 0.86-0.99, respectively. Test-retest reliability ranged from 0.66-1.0 to 0.77-0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements.
Conclusion: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5782436 | PMC |
http://dx.doi.org/10.4103/JCAS.JCAS_61_17 | DOI Listing |
Eye (Lond)
January 2025
Division of Clinical Neuroscience, Department of Ophthalmology, University of Nottingham, Nottingham, UK.
Background/objectives: Anterior segment optical Coherence Tomography (AS-OCT) is used extensively in imaging the cornea in health and disease. Our objective was to analyse and monitor corneal vascularisation (CVas) through the corresponding back-shadows visible on AS-OCT.
Subjects/methods: AS-OCT scans were obtained from 26 consecutive patients (eyes) with CVas of different aetiologies.
Cancers (Basel)
January 2025
Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum Rechts der Isar, Technical University of Munich, 81675 Munich, Germany.
Background: The purpose of this retrospective study was to evaluate the value of contrast-enhanced computed tomography (CE-CT) image features at baseline and after neoadjuvant chemotherapy in predicting histopathological response in patients with adenocarcinoma of the gastroesophageal junction (GEJ).
Methods: A total of 105 patients with a diagnosis of adenocarcinoma of the GEJ were examined by CE-CT at baseline and preoperatively after neoadjuvant chemotherapy. All patients underwent surgical resection.
Biology (Basel)
January 2025
Department of Chemistry, Chung Yuan Christian University, Taoyuan 320314, Taiwan.
Blood flow is an important physiological endpoint to measure cardiovascular performance in animals. Because of their innate transparent bodies, zebrafish is an excellent animal model for assessing in vivo cardiovascular performance. Previously, various helpful methods for measuring blood flow in zebrafish larvae were discovered and developed.
View Article and Find Full Text PDFPLoS One
January 2025
Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Baghdad, Iraq.
This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.
View Article and Find Full Text PDFLasers Med Sci
January 2025
Department of Endodontics, Faculty of Dentistry, Gülhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey.
Objective: This study aims to quantitatively compare the effects of standard needle irrigation (SNI), passive ultrasonic irrigation (PUI), EDDY, photon-initiated photoacoustic streaming (PIPS), and shock wave-enhanced emission photoacoustic streaming (SWEEPS) on the apical extrusion of irrigation solutions in teeth with severe canal curvature.
Materials And Methods: Seventy-five teeth with a single root and canal, and curvature angles ranging from 20° to 40°, were selected for this study. Root canal curvatures were measured from buccolingual and mesiodistal radiographs using ImageJ software (version 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!