The rotary axis is the basis for rotational motion. Its motion errors have critical effects on the accuracy of the related equipment, such as a five-axis computer numerical control machine tool. There are several difficult problems in the implementation of high-precision and fast measurement of the multi-degree-of-freedom motion errors of a rotary axis. In this paper, a novel method for the simultaneous measurement of five-degree-of-freedom motion errors of a rotary axis is proposed, which uses a single-mode fiber-coupled laser with a full-circle measuring range. It has the advantages of high efficiency, low cost, and it requires no decoupling calculation. An experimental system was built and a series of experiments were performed. The standard deviation of stability for 60 min of the five-degree-of-freedom measurement is 0.05 arcsec, 0.06 arcsec, 0.04 μm, 0.03 μm, and 0.19 arcsec, respectively. The repeatability deviation of measuring an indexing table is ± 3.4 arcsec, ± 4.6 arcsec, ± 2.6 μm, ± 2.4 μm, and ± 3.2 arcsec. The maximum deviation of comparison is 3.9 arcsec and 3.2 arcsec. These results demonstrate the effectiveness of the proposed method; thus, a new approach of simultaneous measurement of the multi-degree-of-freedom motion errors of a rotary axis is provided.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.26.002535 | DOI Listing |
Sensors (Basel)
January 2025
School of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, Republic of Korea.
Video frame interpolation (VFI) is a task that generates intermediate frames from two consecutive frames. Previous studies have employed two main approaches to extract the necessary information from both frames: pixel-level synthesis and flow-based methods. However, when synthesizing high-resolution videos using VFI, each approach has its limitations.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Unidad de Investigación en Fisioterapia, Spin off Centro Clínico OMT-E Fisioterapia SLP, Universidad de Zaragoza, Domingo Miral s/n, 50009 Zaragoza, Spain.
The anatomy of the pelvis may obscure differences in pelvic tilt, potentially underestimating its correlation with clinical measures. Measuring the total sagittal range of pelvic movement can serve as a reliable indicator of pelvic function. This study assessed the inter- and intra-examiner reliability of the Kinovea version 0.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Fakultät 1, Brandenburgische Technische Universität Cottbus-Senftenberg, Siemens-Halske-Ring 14, 03046 Cottbus, Germany.
Robot calibration and modelling measurements are commonly performed using a laser tracker. To capture three-dimensional positions, a SMR is attached to the robot. While some researchers employ adhesive bonds for this purpose, such methods often result in inaccurate, unstable and non-repeatable SMR positioning, adversely affecting measurement precision and the traceability of research outcomes.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Engineering for Health Research Centre, Aston University, Aston Triangle, Birmingham B4 7ET, UK.
Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Department of Advanced Medical and Surgical Sciences, University of Campania Luigi Vanvitelli, 80138 Naples, Italy.
: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!