Download full-text PDF

Source

Publication Analysis

Top Keywords

[biomechanical tissue
4
tissue analysis
4
analysis conditions
4
conditions zinc-oxide
4
zinc-oxide paste
4
paste caryophyl
4
caryophyl testing]
4
[biomechanical
1
analysis
1
conditions
1

Similar Publications

Background: Glaucoma, particularly open-angle glaucoma (OAG), is a leading cause of irreversible blindness, associated with optic nerve damage, retinal ganglion cell death, and visual field defects. Corneal biomechanical properties and cellular components, such as corneal nerve and keratocyte densities assessed by in vivo confocal microscopy (IVCM), may serve as biomarkers for glaucoma progression. This study aimed to explore the relationship between corneal nerve parameters, keratocyte density, and optical coherence tomography (OCT)-derived retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) patients and controls.

View Article and Find Full Text PDF

Recurrent sports injuries present complex challenges that extend beyond the playing field, impacting athletes' physical well-being, mental resilience, and financial stability. This review outlines a comprehensive framework designed to prevent and manage these setbacks, empowering athletes to achieve sustained performance and recovery. This multidimensional issue requires an integrative approach encompassing physical rehabilitation, psychological resilience, and nutritional strategies.

View Article and Find Full Text PDF

Thoracolumbar spine muscle size and composition changes in long-duration space missions.

Life Sci Space Res (Amst)

February 2025

Department of Biomedical Engineering, Center for Injury Biomechanics, Wake Forest University School of Medicine. 575 N. Patterson Avenue, Suite 530. Winston-Salem, NC 27101, USA. Electronic address:

Muscle atrophy occurs with extended exposure to microgravity. This study quantified the overall muscle size, lean muscle area and fat infiltration changes pre- to post-flight that occur in the thoracic and lumbar spine with long-duration spaceflight. Pre- and post-flight magnetic resonance imaging (MRI) scans were obtained from 9 crewmembers on long-duration (≥6 months) International Space Station (ISS) missions.

View Article and Find Full Text PDF

Soft tissue-like coupling materials for in vitro acoustic emission studies in total hip arthroplasty.

J Mech Behav Biomed Mater

January 2025

Laboratory for Biomechanics and Biomaterials (LBB), Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Strasse 1-7, 30625, Hannover, Germany. Electronic address:

In hip arthroplasty, relative movements between the femoral stem and bone can lead to implant loosening, resulting in extensive bone loss. Acoustic emission (AE) analysis is a promising technique for a nondestructive and noninvasive detection of these relative movements. To develop such a detection method, in vitro investigations using piezoelectric AE sensors on implant stems in artificial or human femora are required to characterize the AE signals induced by loosening.

View Article and Find Full Text PDF

Background: This study investigated the influence of surgical alignment techniques on knee joint biomechanics during stair negotiation tasks. Our hypothesis was that a more personalized joint alignment would result in reduced medial knee loading biomechanics to negotiate the stairs.

Methods: There were 28 adults (14 mechanical alignments [MA], 14 kinematic alignment [KA]) who underwent total knee arthroplasty (TKA) at least one year post-operatively and performed five stair ascent and descent trials at their preferred velocities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!