Background: Osteoporosis is a costly and morbid disease with the first presentation often with a fragility fracture. The purpose of this study was to assess whether Hounsfield unit (HU) measurements on shoulder computed tomography could identify patients at risk of osteoporosis and aid in its diagnosis.

Methods: We identified patients who had both a computed tomography scan of the glenoid and a dual-energy x-ray absorptiometry scan. Dual-energy x-ray absorptiometry results and HU measurements of the patients' glenoid were recorded. Differences in HU measurements between patients with normal and abnormal central bone mineral density (BMD) were assessed. Correlations were calculated, and receiver operating characteristics were examined.

Results: A total of 51 glenoids met the criteria. The mean glenoid HU measurement was 140.6 (95% confidence interval [CI], 120.1-161.1) in the osteoporotic group, 168.1 (95% CI, 152.7-183.5) in the osteopenic group, and 233.2 (95% CI, 210.1-256.4) in the normal BMD group (P < .001). There was a significant correlation between mean glenoid HU measurement and patients' t scores in the femoral neck (r = 0.581), total hip (r = 0.524), and lumbar spine (r = 0.345). The area under the receiver operating characteristic curve was 0.918. With 197 HUs used as the cutoff for diagnosis of abnormal BMD, the positive predictive value was 96.6%. With 257.1 HUs used as the cutoff, the negative predictive value was 100%.

Conclusion: A patient with an HU measurement below 197 has a 97% chance of having low BMD, and a patient with a measurement over 257 likely has normal BMD. In patients with measurements between these values, a definitive diagnosis should be aggressively pursued. Opportunistic screening for a modifiable disease that has significant morbidity and mortality rates at no additional cost, radiation, or time is of great value.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2017.11.008DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
identify patients
8
bone mineral
8
mineral density
8
dual-energy x-ray
8
x-ray absorptiometry
8
glenoid
4
glenoid neck
4
neck hounsfield
4
hounsfield units
4

Similar Publications

Evaluation of radiation therapy on grafted and non-grafted defects: an experimental rat model.

J Appl Oral Sci

January 2025

Universidade Federal de Uberlândia, Faculdade de Odontologia, Departamento de Periodontia e Implantodontia, Uberlândia, Brasil.

Objective: This study aimed to assess the effects of a single-dose radiation therapy (15 Gy) on grafted and non-grafted defects, bone microarchitecture, and collagen maturity.

Methodology: Bone defects were surgically created in rat femurs. The right femur defect was filled with blood clot (group "Clot") and the left femur defect by deproteinized bovine bone mineral graft (group "Xenograft").

View Article and Find Full Text PDF

Purpose: The degenerative joint disease is a temporomandibular disorder. By analysing texture parameters, it becomes possible to characterize and differentiate various tissues, based on their textural properties according to cone-beam computed tomography (CBCT). This study evaluated degenerative diseases in the temporomandibular joint through texture analysis.

View Article and Find Full Text PDF

Three-dimensional measurement of the depth of invasion in oral squamous cell carcinoma samples using Lugol's iodine-enhanced micro-computed tomography: an original study.

J Appl Oral Sci

January 2025

Nanjing University, Research Institute of Stomatology, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Department of Oral and Maxillofacial Trauma Orthognathic Plastic Surgery, Nanjing, China.

Objectives: Depth of invasion (DOI) in oral squamous cell carcinoma (OSCC) guides treatment and prognosis but lacks three-dimensional (3D) insight. Thus, this study aimed to investigate the feasibility and accuracy of Lugol's iodine-enhanced micro-computed tomography (CT) for the 3D measurement of DOI in OSCC samples.

Methodology: In total, 50 in vitro OSCC samples from Nanjing Stomatological Hospital (July 2022 to January 2024) were subjected to micro-CT imaging with a slice thickness of 50 μm following 3% Lugol iodine staining for 12 h, followed by pathological examination and staining.

View Article and Find Full Text PDF

Unilateral cleft lip and palate patients present cranial base modifications: a cross-sectional study.

Braz Oral Res

January 2025

Pontifícia Universidade Católica de Minas Gerais - PUC Minas, School of Dentistry, Graduate Program in Dentistry, Belo Horizonte, MG, Brazil.

The aim of this cross-sectional study was to perform a three-dimensional (3D) assessment of the cranial base of patients with unilateral cleft lip and palate (UCLP). Cone-beam computed tomography (CBCT) scans of 52 UCLP patients (21 females and 31 males; mean age, 10.0 ± 2.

View Article and Find Full Text PDF

Osteoma is a rare, asymptomatic, and slowly growing benign tumor of bone. Upon reviewing the literature, only 21 cases were previously reported in the mandibular condyle. A 19-year-old male patient presented to the Department of Oral and Maxillofacial Surgery of Ain Shams University complaining of hypomobility and facial asymmetry involving the lower jaw.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!