Accuracy of Cone-beam Computed Tomographic Image Interpretation by Endodontists and Endodontic Residents.

J Endod

Department of Endodontics, Louisiana State University Health Sciences Center, School of Dentistry, New Orleans, Louisiana.

Published: April 2018

Introduction: Limited field cone-beam computed tomography (CBCT) imaging has become a modality frequently used by endodontists to evaluate the teeth and surrounding tissues of their patients. Accurate image interpretation is vital to obtain needed treatment information as well as to discern coincidental findings that could be present. The goal of this study was to determine the accuracy of CBCT volume interpretation when performed by endodontists and endodontic residents.

Methods: Eighteen deidentified limited field CBCT scans were obtained and evaluated by an oral and maxillofacial radiologist and an endodontist experienced in reading CBCT images. Their collective findings were combined as the "gold standard" of interpretation for this investigation. Using standard CBCT software, 4 practicing endodontists and 5 second-year endodontic residents evaluated each scan and recorded any notable findings and whether or not each scan warranted referral to a radiology specialist. Their interpretations were then compared with the gold standard to determine accuracy and any significant differences among the groups.

Results: The overall accuracy was 58.3% for endodontists and 64.3% for residents. Paired t tests showed no statistically significant differences in accuracy between the 2 groups for findings in teeth or in bone, but residents were significantly better for maxillary sinus findings. Endodontists agreed with the gold standard 38.9% of the time and residents 49.8% of the time on necessity of referral. The Cohen kappa coefficient showed moderate agreement between the groups.

Conclusions: Endodontists and residents had similar accuracy in CBCT scan evaluation. More training and experience are warranted for both groups in order to maximize image assessment accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2017.12.012DOI Listing

Publication Analysis

Top Keywords

cone-beam computed
8
image interpretation
8
endodontists endodontic
8
endodontic residents
8
limited field
8
determine accuracy
8
accuracy cbct
8
gold standard
8
accuracy
7
endodontists
7

Similar Publications

Buccal cortical bone dimensions are crucial in dental radiology, as they impact orthodontic treatment outcomes. Changes in alveolar bone dimensions can result in malocclusion and require interdisciplinary approaches for correction. The accurate quantification of buccal bone dimensions is crucial for appropriate treatment planning and avoiding medico-legal issues.

View Article and Find Full Text PDF

Measurements of tooth size for estimating inter-arch tooth size discrepancies and inter-tooth distances, essential for orthodontic diagnosis and treatment, are primarily done using traditional methods involving plaster models and calipers. These methods are time-consuming and labor-intensive, requiring multiple steps. With advances in cone-beam computerized tomography (CBCT) and intraoral scanning technology, these processes can now be automated through computer analyses.

View Article and Find Full Text PDF

Objectives: Minimally invasive surgery (MIS) has emerged as a promising alternative to conventional open techniques in the management of adolescent idiopathic scoliosis (AIS).

Materials And Methods: This study presents a case series of six patients who underwent MIS for AIS at a spine center, employing a synergistic blend of intraoperative fluoroscopy, cone-beam computed tomography scans, and three-dimensional navigation technology. The surgical procedures were meticulously guided, with a focus on ensuring safety and precision in posterior pedicle fixation.

View Article and Find Full Text PDF

This study investigates whether an Image-Guided Radiation Therapy (IGRT) workbook and Cone Beam Computed Tomography (CBCT) case studies enhances Radiation Therapists' (RTTs) confidence analysing Proton Beam Therapy (PBT) CBCTs. An 11-participant questionnaire-based study was conducted to assess pre- and post-training confidence. Prior to training, RTTs exhibited higher confidence in photon CBCT decision-making over proton CBCT, highlighting the need for PBT-specific IGRT training, irrespective of prior photon experience.

View Article and Find Full Text PDF

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis.

Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm-thick aligners and horizontal attachments, were integrated into the software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!