AI Article Synopsis

  • This study investigated the macular 3D-OCT images in patients with Vogt-Koyanagi-Harada (VKH) disease, focusing on their unique imaging characteristics and their significance in diagnosing VKH.
  • The analysis included 50 eyes from 25 VKH patients, revealing high occurrences of features such as retinal edema (98%), endometrium-like structures (72%), and irregularities in internal layers of the retina.
  • The findings indicate that retinal thickness abnormalities and irregular uplift patterns are common in VKH, suggesting specific OCT features that are crucial for diagnosis.

Article Abstract

BACKGROUND This study analyzed the macular 3D-OCT images of Vogt-Koyanagi-Harada disease (VKH) in uveitis, explored the characteristics of 3D-OCT images of the macular region of VKH, and assessed which characteristics contribute most to VKH diagnosis. MATERIAL AND METHODS The 3D-OCT examination of 25 cases of VKH was performed on the macular area, and the image characteristics were analyzed. RESULTS Our study included a total of 50 eyes from 25 cases of VKH patients, 10 males and 15 females, aged 17 to 64 years, mean (39.44±11.60) years old. According to OCT B-scan images, 49 (98%) eyes had ERD, 49 (98%) eyes had nerve retinal edema, 36 (72%) eyes had endometrium-like structure (including cysts), 5 (10%) eyes had RPE folds, 35 (70%) eyes had changes in the internal septum, 49 (98%) eyes had RPE monolayer structure outside the ERD region. In ILM-RPE thickness, 49 (98%) eyes had retinal irregular thickening and 31 (62%) eyes had radial stripe changes. In ILM contour figure, 50 eyes (100%) showed exceptional uplift, 5 (10%) eyes had small focal uplift for PED on the RPE surface, and 48 (96%) eyes had wavy ups and downs. CONCLUSIONS In OCT B-scan imaging, the ERT, retinal edema of the retina, and the RPE monolayer structure outside the range are most likely to occur in VKH. The ILM-RPE thickness chart in 3D reconstruction showed irregular thickening of the retina. The ILM contour graph showed abnormal uplift, and RPE surface wavy ups and downs in VKH most likely to occur.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5807914PMC
http://dx.doi.org/10.12659/msm.905931DOI Listing

Publication Analysis

Top Keywords

98% eyes
16
eyes
12
vogt-koyanagi-harada disease
8
3d-oct images
8
cases vkh
8
oct b-scan
8
retinal edema
8
10% eyes
8
eyes rpe
8
rpe monolayer
8

Similar Publications

Purpose: The purpose of this study was to analyze the retinal sensitivity under photopic, mesopic, and scotopic conditions in a cohort of patients affected with KCNV2-associated retinopathy.

Methods: Cross-sectional evaluation of molecularly confirmed individuals was conducted. Data were obtained prospectively.

View Article and Find Full Text PDF

There is a lack of research on the clinical characteristics of vitreomacular traction (VMT) in the Central Asian population, which evaluates the visual recovery and macular hole closure outcomes of pars plana vitrectomy (PPV) with membrane peel in this population. This long-term prospective cohort study, conducted at the Kazakh Eye Research Institute from June 2015 to December 2021 with a follow-up period until December 2022, included 1574 patients (1784 eyes) with VMT syndrome. Among the eyes, 724 (40.

View Article and Find Full Text PDF

Improving Real-Time Feedback During Cochlear Implantation: The Auditory Nerve Neurophonic/Cochlear Microphonic Ratio.

Ear Hear

January 2025

Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.

Objectives: Real-time monitoring of cochlear function to predict the loss of residual hearing after cochlear implantation is now possible. Current approaches monitor the cochlear microphonic (CM) during implantation from the electrode at the tip of the implant. A drop in CM response of >30% is associated with poorer hearing outcomes.

View Article and Find Full Text PDF

Purpose: To validate automated counts of presumed anterior chamber (AC) cells in eyes with histories of uveitis involving the anterior segment using swept-source (SS) anterior segment optical coherence tomography (AS-OCT) against manual counts and compare automated counts against Standardized Uveitis Nomenclature (SUN) criteria.

Methods: Eyes were imaged with the ANTERION SS AS-OCT device (Heidelberg Engineering). A fully automated custom algorithm quantified the number of hyper-reflective foci (HRF) in line-scan images.

View Article and Find Full Text PDF

Background: over the past decade, a bi‐directional relationship between sleep and Alzheimer’s disease (AD) has been increasingly recognized, with several studies suggesting a link between self‐reported sleep disturbances and AD biomarkers. However, the association between polysomnography (PSG)‐assessed sleep parameters and AD biomarkers remains unknown.

Method: We examined 128 participants [mean age 70.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!