Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To clarify the concordance rate of the location of uptake on positron emission tomography/computed tomography (PET/CT) and the impingement point demonstrated in computer simulation in femoroacetabular impingement (FAI) syndrome with cam morphology.
Methods: We included hip joints with FAI syndrome that underwent F-fluoride PET/CT. We also excluded hips with SUV <6. Each hip was evaluated for the region of the SUV point on PET/CT as well as the impingement point by computer simulation. We used ZedHip software (Lexi, Tokyo, Japan) for impingement simulation analysis based on CT data. Bony impingement is identified if there is a mesh in acetabular and femoral side contact in at least one unit. We investigated the rate of concordance between these 2 regions for each 10° flexion angle of the hip, ranging from 0° to 90°.
Results: Twenty-two hips of 22 patients were evaluated. The SUV region was most frequently distributed in the proximal middle region in 12 hips. In 18 of 22 hips (81.8%), the SUV region was concordant with the impingement region for at least one flexion angle. The concordance rates in 50° (P = .034), 60° (P = .007), 70° (P = .011), and 80° (P = .046) of flexion were significantly higher than in 90° of flexion.
Conclusions: It was possible to visualize and clarify the detailed location of abnormal uptake in FAI syndrome patients with cam morphology by applying F-fluoride PET/CT. The concordance rates in 50°, 60°, 70°, and 80° of flexion were significantly higher than in 90° of flexion, which suggested that impingement may more frequently occur at less than 90° of flexion in FAI syndrome with cam morphology.
Level Of Evidence: Level III, cross-sectional diagnostic study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2017.10.055 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!