Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Accelerated Molecular Dynamics (aMD) is a promising enhanced sampling method to explore the conformational space of biomolecules. However, the large statistical noise in reweighting limits its accuracy to recover the original free energy profile. In this work, we propose an Integrated accelerated Molecule Dynamics (IaMD) method by integrating a series of aMD subterms with different acceleration parameters to improve the sampling efficiency and maintain the reweighting accuracy simultaneously. We use Alanine Dipeptide and three fast-folded proteins (Chignolin, Trp-cage, and Villin Headpiece) as the test objects to compare our IaMD method with aMD systematically. These case studies indicate that the statistical noise of IaMD in reweighting for free energy profiles is much smaller than that of aMD at the same level of acceleration and simulation time. To achieve the same accuracy as IaMD, aMD requires 1-3 orders of magnitude longer simulation time, depending on the complexity of the simulated system and the level of acceleration. Our method also outperforms aMD in controlling systematic error caused by the disappearance of the low-energy conformations when high acceleration parameters are used in aMD simulations for fast-folded proteins. Furthermore, the performance comparison between IaMD and the Integrated Tempering Sampling (ITS) in the case of Alanine Dipeptide demonstrates that IaMD possesses a better ability to control the potential energy region of sampling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.jctc.7b01211 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!