Purpose: Diagnostic recommendations for acquired apraxia of speech (AOS) have been contradictory concerning whether speech sound errors are consistent or variable. Studies have reported divergent findings that, on face value, could argue either for or against error consistency as a diagnostic criterion. The purpose of this study was to explain discrepancies in error consistency results based on the unit of analysis (segment, syllable, or word) to help determine which diagnostic recommendation is most appropriate.
Method: We analyzed speech samples from 14 left-hemisphere stroke survivors with clinical diagnoses of AOS and aphasia. Each participant produced 3 multisyllabic words 5 times in succession. Broad phonetic transcriptions of these productions were coded for consistency of error location and type using the word and its constituent syllables and sound segments as units of analysis.
Results: Consistency of error type varied systematically with the unit of analysis, showing progressively greater consistency as the analysis unit changed from the word to the syllable and then to the sound segment. Consistency of error location varied considerably across participants and correlated positively with error frequency.
Conclusions: Low to moderate consistency of error type at the word level confirms original diagnostic accounts of speech output and sound errors in AOS as variable in form. Moderate to high error type consistency at the syllable and sound levels indicate that phonetic error patterns are present. The results are complementary and logically compatible with each other and with the literature.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1044/2017_JSLHR-S-16-0381 | DOI Listing |
Rev Sci Instrum
January 2025
School of Electronic Engineering, Heilongjiang University, Harbin, HeiLongJiang 150080, China.
Gluing is a critical step in aircraft sealing assembly, with glue profile inspection serving as the final quality assurance measure to ensure consistency and accuracy of the sealant coating, allowing timely detection and correction of defects to maintain assembly integrity and safety. Currently, existing glue inspection systems are limited to basic inspection capabilities, lack result digitization, and exhibit low efficiency. This paper proposes a 3D inspection technology for sealant coating quality based on line-structured light, enabling automated and high-precision inspection of sealant thickness, sealant width, positional accuracy, and overlap joint sealant contour through geometric computation.
View Article and Find Full Text PDFJ Chem Phys
January 2025
Department of Chemistry and Biochemistry, School of Advanced Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555, Japan.
The self-consistent field (SCF) procedure is the standard technique for solving the Hartree-Fock and Kohn-Sham density functional theory calculations, while convergence is not theoretically guaranteed. Direct minimization methods, such as the augmented Lagrangian method (ALM) and second-order SCF (SOSCF), obtain the SCF solution by minimizing the Lagrangian with the gradient. In SOSCF, molecular orbitals are optimized by truncating the Taylor expansion of a unitary matrix represented in exponential form to ensure the orthonormality condition.
View Article and Find Full Text PDFGen Hosp Psychiatry
December 2024
National Sleep Foundation, Washington, DC 20036, USA.
Objective: The RU_SATED scale is increasingly used across the globe to measure sleep health. However, there is a lack of consensus around its psychometric and diagnostic performance. We conducted an empirical investigation into the psychometrics of the Chinese version of the RU_SATED (RU_SATED-C) scale, with a focus on structural validity and diagnostic performance.
View Article and Find Full Text PDFEnviron Technol
December 2024
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, People's Republic of China.
The moisture content (MC) of sludge is a critical factor affecting sludge treatment and disposal technologies. Traditional drying methods for measuring sludge MC are time-consuming and lack of portability. To achieve rapid online detection of sludge MC, this paper proposes a method based on frequency domain reflectometry.
View Article and Find Full Text PDFExp Brain Res
December 2024
Department of Kinesiology, The Pennsylvania State University, University Park, PA, 16802, USA.
Accurate control of force on the environment is mechanically necessary for many tasks involving the lower extremities. We investigated drifts in the horizontal (shear) active force produced by right-footed seated subjects and the effects of force matching by the other foot. Subjects generated constant shear force at 15% and 30% of maximal voluntary contraction (MVC) using one foot.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!