Assessment of radiation safety in cardiac CT angiography.

Medicine (Baltimore)

Department of Radiology, Wan Fang Hospital, Taipei Medical University Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan, Republic of China.

Published: December 2017

This study investigates the radiation dose and image quality of patients not receiving β-blockers for cardiac CT angiography (CCTA) with or without the optimization of electrocardiographic (ECG) pulsing window. The differences in patient characteristics are also characterized.Normal-weight and obese patients (n = 154) with heart rates between 65 and 80 beats per minutes (bpm) during the prospective axial scanning were enrolled retrospectively. The ECG pulsing windows were set at 50% to 75% (Group A) or 60% to 75% (Group B) of the R-R interval for patients with heart rate variability higher than or not exceeding ±5 bpm, respectively. The effective doses of individual patient were estimated from the dose length product of the CCTA scan. Two radiologists independently reviewed the images and applied a 4-point Likert scale for image quality assessment. The patients' characteristics were compared along with the patients' effective doses between groups.The optimized pulsing window significantly reduced the average radiation dose for normal-weight and obese patients by 33% and 27%, respectively. The CCTA image quality of patients in Group A was not different overall from those obtained from Group B. Nondiabetic obese patients were more likely to be accepted for the use of the optimized pulsing window. Unlike obese patients, normal-weight patients revealed no characteristic difference between Groups A and B.This study indicates an equivalent efficacy of using optimized pulsing windows for reducing the radiation dose for patients without β-blocker administration between different body weight groups. Nevertheless, gender and diabetic status became prominent characteristics in the obese group when matching up with the optimized pulsing window.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5758200PMC
http://dx.doi.org/10.1097/MD.0000000000009305DOI Listing

Publication Analysis

Top Keywords

pulsing window
16
obese patients
16
optimized pulsing
16
radiation dose
12
image quality
12
patients
9
cardiac angiography
8
quality patients
8
ecg pulsing
8
pulsing windows
8

Similar Publications

Predicting right ventricular failure after left ventricular assist device implant: A novel approach.

ESC Heart Fail

January 2025

Division of Cardiology, Department of Medicine, Hospital of the University of Pennsylvania, Perelman School of Medicine, Philadelphia, Pennsylvania, USA.

Aims: Right ventricular (RV) failure (RVF) after left ventricular assist device (LVAD) implant is an important cause of morbidity and mortality. Modern, data-driven approaches for defining and predicting RVF have been under-utilized.

Methods: Two hundred thirty-two patients were identified with a mean age of 55 years; 40 (17%) were women, 132 were (59%) Caucasian and 74 (32%) were Black.

View Article and Find Full Text PDF

Fabrication of hierarchical sapphire nanostructures using ultrafast laser induced morphology change.

Nanotechnology

January 2025

Walker Department of Mechanical Engineering, The University of Texas at Austin, 204 E. Dean Keeton St., Austin, Texas, 78712-1139, UNITED STATES.

Sapphire is an attractive material in photonic, optoelectronic, and transparent ceramic applications that stand to benefit from surface functionalization effects stemming from micro/nanostructures. Here we investigate the use of ultrafast lasers for fabricating nanostructures in sapphire by exploring the relationship between irradiation parameters, morphology change, and selective etching. In this approach an ultrafast laser pulse is focused on the sapphire substrate to change the crystalline morphology to amorphous or polycrystalline, which is characterized by examining different vibrational modes using Raman spectroscopy.

View Article and Find Full Text PDF

The acute effect of bitemporal electroconvulsive therapy on synchronous changes in heart rate variability and heart rate in patients with depression.

Physiol Meas

January 2025

The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Institute of Health and Rehabilitation Science, School of Life Science and Technology, Xi'an Jiaotong University, No.28 west Xianning Rd, Xi'an, 710049, CHINA.

The transient autonomic nervous system responses induced by electroconvulsive therapy (ECT) may serve as critical indicators of treatment efficacy and potential side effects; however, their precise characteristics remains unclear. Considering that the intense stimulation of ECT may disrupt the typical antagonistic relationship between the sympathetic and parasympathetic branches, this study aims to conduct a meticulous analysis of the rapid changes in heart rate variability and heart rate during ECT, with a particular focus on their synchronized interplay. Methods: Pulse interval sequences were collected from fifty sessions of bitemporal ECT administered to twenty-seven patients diagnosed with major depressive disorder.

View Article and Find Full Text PDF

Background And Purpose: Successful and complete reperfusion should be the aim of every endovascular thrombectomy (EVT) procedure. However, the effect of time delays on successful reperfusion in late window stroke patients presenting 6-to-24 h from onset has not been investigated.

Materials And Methods: We pooled individual patient-level data from seven trials and registries for anterior circulation stroke patients treated with EVT between 6 and 24 h from onset.

View Article and Find Full Text PDF

A parallelized field-programmable gate array (FPGA) architecture is proposed to realize an ultra-fast, compact, and low-cost dual-channel ultra-wideband (UWB) pulsed-radar system. This approach resolves the main shortcoming of current FPGA-based radars, namely their low processing throughput, which leads to a significant loss of data provided by the radar receiver. The architecture is integrated with an in-house UWB pulsed radar operating at a sampling rate of 20 gigasamples per second (GSa/s).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!