  • This study investigates the effectiveness of coronary computed tomography angiography (CCTA) in diagnosing significant coronary artery disease (CAD) in patients being considered for aortic valve replacement (AVR), using invasive coronary angiography (ICA) as the benchmark.
  • A review of thirteen studies involving 1498 patients showed a 43% prevalence of significant stenosis, with CCTA demonstrating high sensitivity (95%) and reasonable specificity (79%) in identifying CAD.
  • The findings suggest that CCTA could be a beneficial diagnostic tool before AVR surgeries, but further research is needed to fully understand its role in preoperative planning.

Article Abstract

Purpose: In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard.

Materials And Methods: We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft.

Results: Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR.

Conclusions: Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RTI.0000000000000322DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
16
patients referred
12
accuracy coronary
8
coronary computed
8
computed tomography
8
aortic valve
8
valve replacement
8
aortic stenosis
8
surgical transcatheter
8
ccta
8

Similar Publications

Surgical techniques and prognostic nomogram for patients with supravalvular aortic stenosis.

Eur J Med Res

January 2025

Department of Pediatric Cardiac Center, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China.

Background: An effective prognostic nomogram to predict the prognosis for supravalvular aortic stenosis (SVAS) patients is lacking.

Methods: A multi-center retrospective study of consecutive SVAS patients with surgery between 2002 and 2020 was conducted. Patients underwent McGoon repairs, Doty repairs, and other repairs.

View Article and Find Full Text PDF

Background: Faecal egg counts (FECs) are essential for diagnosing helminth infections and guiding treatment decisions. For camels, no evaluations of coproscopic methods regarding precision, sensitivity and correlation between individual and pooled faecal samples are currently available.

Methods: Here, 410 camel faecal samples were collected in 2022 from South Darfur State, Sudan, and analysed to compare the semi-quantitative flotation, McMaster and Mini-FLOTAC methods in terms of precision, sensitivity, inter-rater reliability and helminth egg count correlations, as well as the effects of pooling samples.

View Article and Find Full Text PDF

Study Design: Systematic review.

Objective: Artificial intelligence (AI) and deep learning (DL) models have recently emerged as tools to improve fracture detection, mainly through imaging modalities such as computed tomography (CT) and radiographs. This systematic review evaluates the diagnostic performance of AI and DL models in detecting cervical spine fractures and assesses their potential role in clinical practice.

View Article and Find Full Text PDF

Hypochlorous acid (HClO) is a well-known inflammatory signaling molecule, while lipid droplets (LDs) are dynamic organelles closely related to inflammation. Using organic small-molecule fluorescence imaging technology to target LDs for precise monitoring of HClO is one of the most effective methods for diagnosing inflammation-related diseases. A thorough investigation of how probes detect biological markers and the influencing factors can aid in the design of probe molecules, the selection of high-performance tools, and the accuracy of disease detection.

View Article and Find Full Text PDF

A New Anti-Interfering Platelet Counting Technology Utilizing Conventional Impedance and White Blood Cell Differential Channel.

Int J Lab Hematol

January 2025

Department of Laboratory Medicine, The Third Xiangya Hospital, Central South University, Changsha, People's Republic of China.

Introduction: Accurate platelet (PLT) counting is crucial for disease diagnosis and treatment, especially under the condition of thrombocytopenia and platelet transfusion. A few PLT counting approaches have been established including impedance and fluorescent methods. The impedance PLT counting (PLT-I) approach could be interfered by small non-PLT particles in the blood, such as RBC/WBC fragments, microcytes, bacteria, and cryoglobulins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!